| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Adobe Digital Editions versions 4.5.4 and earlier contain an insecure library loading vulnerability. The vulnerability is due to unsafe library loading functions in the installer plugin. A successful exploitation could lead to arbitrary code execution. |
| An Uncontrolled Search Path Element issue was discovered in BLF-Tech LLC VisualView HMI Version 9.9.14.0 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code. |
| In Adam Kropelin adk0212 APC UPS Daemon through 3.14.14, the default installation of APCUPSD allows a local authenticated, but unprivileged, user to run arbitrary code with elevated privileges by replacing the service executable apcupsd.exe with a malicious executable that will run with SYSTEM privileges at startup. This occurs because of "RW NT AUTHORITY\Authenticated Users" permissions for %SYSTEMDRIVE%\apcupsd\bin\apcupsd.exe. |
| Code injection vulnerability in Avast Premier 12.3 (and earlier), Internet Security 12.3 (and earlier), Pro Antivirus 12.3 (and earlier), and Free Antivirus 12.3 (and earlier) allows a local attacker to bypass a self-protection mechanism, inject arbitrary code, and take full control of any Avast process via a "DoubleAgent" attack. One perspective on this issue is that (1) these products do not use the Protected Processes feature, and therefore an attacker can enter an arbitrary Application Verifier Provider DLL under Image File Execution Options in the registry; (2) the self-protection mechanism is intended to block all local processes (regardless of privileges) from modifying Image File Execution Options for these products; and (3) this mechanism can be bypassed by an attacker who temporarily renames Image File Execution Options during the attack. |
| In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. |
| In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, a local authenticated user can load a maliciously crafted file in the search path which may potentially allow the attacker to execute arbitrary code on the targeted VNX Control Station system, aka an uncontrolled search path vulnerability. |
| Adobe Digital Editions versions 4.5.4 and earlier contain an insecure library loading vulnerability. The vulnerability is due to unsafe library loading of browser related library extensions in the installer plugin. A successful exploitation could lead to arbitrary code execution. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll file placed earlier in the search path may allow an attacker to execute code within the context of the application. |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. |
| Symantec VIP Access for Desktop prior to 2.2.4 can be susceptible to a DLL Pre-Loading vulnerability. These types of issues occur when an application looks to call a DLL for execution and an attacker provides a malicious DLL to use instead. Depending on how the application is configured, the application will generally follow a specific search path to locate the DLL. The exploitation of the vulnerability manifests as a simple file write (or potentially an over-write) which results in a foreign executable running under the context of the application. |
| There exists a path traversal vulnerability in the Android Google Search app. This is caused by the incorrect usage of uri.getLastPathSegment. A symbolic encoded string can bypass the path logic to get access to unintended directories. An attacker can manipulate paths that could lead to code execution on the device. We recommend upgrading beyond version 13.41 |
| Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started. |
| AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. |
| DWG TrueViewTM 2023 version has a DLL Search Order Hijacking vulnerability. Successful exploitation by a malicious attacker could result in remote code execution on the target system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems. |
| Delta Electronics DIAEnergie (all versions prior to 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an attacker to escalate privileges |
| The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22. |
| AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; |
| If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application’s context and permissions. |