| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| There is a reachable assertion abort in the function TIFFWriteDirectoryTagSubifd() in LibTIFF 4.0.8, related to tif_dirwrite.c and a SubIFD tag. A crafted input will lead to a remote denial of service attack. |
| kernel/bpf/verifier.c in the Linux kernel through 4.14.8 allows local users to cause a denial of service (memory corruption) or possibly have unspecified other impact by leveraging mishandling of 32-bit ALU ops. |
| contrib/slapd-modules/nops/nops.c in OpenLDAP through 2.4.45, when both the nops module and the memberof overlay are enabled, attempts to free a buffer that was allocated on the stack, which allows remote attackers to cause a denial of service (slapd crash) via a member MODDN operation. |
| There is a reachable assertion abort in the function jpc_pi_nextrpcl() in jpc/jpc_t2cod.c in JasPer 2.0.12 that will lead to a remote denial of service attack. |
| IBM Curam Social Program Management 6.0 and 7.0 are vulnerable to a denial of service, caused by an XML External Entity Injection (XXE) error when processing XML data. A remote attacker could exploit this vulnerability to expose highly sensitive information or consume all available memory resources. IBM Reference #: 2000833. |
| The Milwaukee ONE-KEY Android mobile application uses bearer tokens with an expiration of one year. This bearer token, in combination with a user_id can be used to perform user actions. |
| EMC Documentum eRoom version 7.4.4, EMC Documentum eRoom version 7.4.4 SP1, EMC Documentum eRoom version prior to 7.4.5 P04, EMC Documentum eRoom version prior to 7.5.0 P01 includes an unverified password change vulnerability that could potentially be exploited by malicious users to compromise the affected system. |
| The hidden-service feature in Tor before 0.3.0.8 allows a denial of service (assertion failure and daemon exit) in the relay_send_end_cell_from_edge_ function via a malformed BEGIN cell. |
| IBM WebSphere Commerce Enterprise, Professional, Express, and Developer 6.0, 7.0, and 8.0 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially-crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 127385. |
| Windows Performance Monitor in Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows an information disclosure vulnerability due to the way it parses XML input, aka "Windows Performance Monitor Information Disclosure Vulnerability". |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. |
| slapd in OpenLDAP 2.4.45 and earlier creates a PID file after dropping privileges to a non-root account, which might allow local users to kill arbitrary processes by leveraging access to this non-root account for PID file modification before a root script executes a "kill `cat /pathname`" command, as demonstrated by openldap-initscript. |
| A vulnerability in the web-based user interface of Cisco Prime Infrastructure (PI) and Evolved Programmable Network Manager (EPNM) could allow an authenticated, remote attacker read and write access to information stored in the affected system as well as perform remote code execution. The attacker must have valid user credentials. The vulnerability is due to improper handling of XML External Entity (XXE) entries when parsing an XML file. An attacker could exploit this vulnerability by convincing the administrator of an affected system to import a crafted XML file with malicious entries which could allow the attacker to read and write files and execute remote code within the application, aka XML Injection. Cisco Prime Infrastructure software releases 1.1 through 3.1.6 are vulnerable. Cisco EPNM software releases 1.2, 2.0, and 2.1 are vulnerable. Cisco Bug IDs: CSCvc23894 CSCvc49561. |
| An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a user, the application does not require the user to know the original password. An attacker who is authenticated could change a user's password, enabling future access and possible configuration changes. |
| XML external entity (XXE) vulnerability in Umbraco CMS before 7.7.3 allows attackers to obtain sensitive information by reading files on the server or sending TCP requests to intranet hosts (aka SSRF), related to Umbraco.Web/umbraco.presentation/umbraco/dialogs/importDocumenttype.aspx.cs. |
| An issue in ZKTeko BioTime v.8.5.4 and before allows a remote attacker to obtain sensitive information via the Authentication & Authorization component |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| An “uninitialized variable” code execution vulnerability exists in the
Rockwell Automation Arena®
that could allow a threat actor to craft a DOE file and force the software to access a variable before it being initialized. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. |