Search Results (84431 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-31934 1 Open-xchange 1 Open-xchange Appsuite 2024-11-21 6.1 Medium
OX App Suite 7.10.4 and earlier allows XSS via a crafted contact object (payload in the position or company field) that is mishandled in the App Suite UI on a smartphone.
CVE-2021-31933 1 Chamilo 1 Chamilo 2024-11-21 7.2 High
A remote code execution vulnerability exists in Chamilo through 1.11.14 due to improper input sanitization of a parameter used for file uploads, and improper file-extension filtering for certain filenames (e.g., .phar or .pht). A remote authenticated administrator is able to upload a file containing arbitrary PHP code into specific directories via main/inc/lib/fileUpload.lib.php directory traversal to achieve PHP code execution.
CVE-2021-31930 1 Concerto-signage 1 Concerto 2024-11-21 6.1 Medium
Persistent cross-site scripting (XSS) in the web interface of Concerto through 2.3.6 allows an unauthenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into the First Name or Last Name parameter upon registration. When a privileged user attempts to delete the account, the XSS payload will be executed.
CVE-2021-31929 1 Annexcloud 1 Loyalty Experience Platform 2024-11-21 4.3 Medium
Annex Cloud Loyalty Experience Platform <2021.1.0.1 allows any authenticated attacker to modify loyalty campaigns and settings, such as fraud prevention, coupon groups, email templates, or referrals.
CVE-2021-31920 2 Istio, Redhat 2 Istio, Service Mesh 2024-11-21 6.5 Medium
Istio before 1.8.6 and 1.9.x before 1.9.5 has a remotely exploitable vulnerability where an HTTP request path with multiple slashes or escaped slash characters (%2F or %5C) could potentially bypass an Istio authorization policy when path based authorization rules are used.
CVE-2021-31918 1 Redhat 1 Openstack 2024-11-21 7.5 High
A flaw was found in tripleo-ansible version as shipped in Red Hat Openstack 16.1. The Ansible log file is readable to all users during stack update and creation. The highest threat from this vulnerability is to data confidentiality.
CVE-2021-31916 3 Debian, Linux, Redhat 3 Debian Linux, Linux Kernel, Enterprise Linux 2024-11-21 6.7 Medium
An out-of-bounds (OOB) memory write flaw was found in list_devices in drivers/md/dm-ioctl.c in the Multi-device driver module in the Linux kernel before 5.12. A bound check failure allows an attacker with special user (CAP_SYS_ADMIN) privilege to gain access to out-of-bounds memory leading to a system crash or a leak of internal kernel information. The highest threat from this vulnerability is to system availability.
CVE-2021-31915 1 Jetbrains 1 Teamcity 2024-11-21 9.8 Critical
In JetBrains TeamCity before 2020.2.4, OS command injection leading to remote code execution was possible.
CVE-2021-31911 1 Jetbrains 1 Teamcity 2024-11-21 6.1 Medium
In JetBrains TeamCity before 2020.2.3, reflected XSS was possible on several pages.
CVE-2021-31908 1 Jetbrains 1 Teamcity 2024-11-21 5.4 Medium
In JetBrains TeamCity before 2020.2.3, stored XSS was possible on several pages.
CVE-2021-31907 1 Jetbrains 1 Teamcity 2024-11-21 5.3 Medium
In JetBrains TeamCity before 2020.2.2, permission checks for changing TeamCity plugins were implemented improperly.
CVE-2021-31904 1 Jetbrains 1 Teamcity 2024-11-21 6.1 Medium
In JetBrains TeamCity before 2020.2.2, XSS was potentially possible on the test history page.
CVE-2021-31903 1 Jetbrains 1 Youtrack 2024-11-21 6.1 Medium
In JetBrains YouTrack before 2021.1.9819, a pull request's title was sanitized insufficiently, leading to XSS.
CVE-2021-31902 1 Jetbrains 1 Youtrack 2024-11-21 7.5 High
In JetBrains YouTrack before 2020.6.6600, access control during the exporting of issues was implemented improperly.
CVE-2021-31894 1 Siemens 8 Simatic Pcs 7, Simatic Pcs 7 Firmware, Simatic Pdm and 5 more 2024-11-21 8.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
CVE-2021-31891 2 Debian, Siemens 6 Debian Linux, Desigo Cc, Gma-manager and 3 more 2024-11-21 10.0 Critical
A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges.
CVE-2021-31888 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 8.8 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
CVE-2021-31887 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 8.8 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
CVE-2021-31886 1 Siemens 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more 2024-11-21 9.8 Critical
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
CVE-2021-31875 1 Cesanta 1 Mongooseos Mjs 2024-11-21 9.8 Critical
In mjs_json.c in Cesanta MongooseOS mJS 1.26, a maliciously formed JSON string can trigger an off-by-one heap-based buffer overflow in mjs_json_parse, which can potentially lead to redirection of control flow. NOTE: the original reporter disputes the significance of this finding because "there isn’t very much of an opportunity to exploit this reliably for an information leak, so there isn’t any real security impact."