| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| OS command injection in Ivanti Endpoint Manager Mobile (EPMM) before version 12.5.0.2,12.4.0.3 and 12.3.0.3 allows a remote authenticated attacker with high privileges to achieve remote code execution |
| In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation. Patch ID: WCNCR00416939; Issue ID: MSV-3422. |
|
MicroDicom DICOM Viewer versions 2023.3 (Build 9342) and prior are affected by a heap-based buffer overflow vulnerability, which could allow an attacker to execute arbitrary code on affected installations of DICOM Viewer. A user must open a malicious DCM file in order to exploit the vulnerability.
|
| An out-of-bounds write in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to cause a denial of service. |
| A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.17(9502). This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261983. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical has been found in TOTOLINK X18 9.1.0cu.2024_B20220329. Affected is the function setPasswordCfg of the file /cgi-bin/cstecgi.cgi. The manipulation as part of String leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.17(9502). Affected is the function modifyDhcpRule of the file /goform/modifyDhcpRule. The manipulation of the argument bindDhcpIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261984. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 2). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromAddressNat of the file /goform/addressNat. The manipulation of the argument entrys leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 2). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
| An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
|
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted ASM files. This could allow an attacker to execute code in the context of the current process. |
|
MicroDicom DICOM Viewer versions 2023.3 (Build 9342) and prior contain a lack of proper validation of user-supplied data, which could result in memory corruption within the application.
|
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability was found in TOTOLINK X18 9.1.0cu.2024_B20220329. It has been rated as critical. This issue affects the function setL2tpdConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument enable leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is some unknown functionality of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. |