CVE-2025-10392 1 Mercury 1 Km08-708h Giga Wifi Wave2 2026-04-15 9.8 Critical
A vulnerability was detected in Mercury KM08-708H GiGA WiFi Wave2 1.1.14. This affects an unknown function of the component HTTP Header Handler. The manipulation of the argument Host results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
CVE-2024-49397 1 Elvaco 1 Cme3100 Firmware 2026-04-15 N/A
The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts.
CVE-2024-13955 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 8.8 High
2nd Order SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if administrator credentials become compromised.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
CVE-2024-4826 2026-04-15 9.8 Critical
SQL injection vulnerability in Simple PHP Shopping Cart affecting version 0.9. This vulnerability could allow an attacker to retrieve all the information stored in the database by sending a specially crafted SQL query, due to the lack of proper sanitisation of the category_id parameter in the category.php file.
CVE-2024-56841 2026-04-15 7.4 High
A vulnerability has been identified in Mendix LDAP (All versions < V1.1.2). Affected versions of the module are vulnerable to LDAP injection. This could allow an unauthenticated remote attacker to bypass username verification.
CVE-2024-56732 2026-04-15 8.8 High
HarfBuzz is a text shaping engine. Starting with 8.5.0 through 10.0.1, there is a heap-based buffer overflow in the hb_cairo_glyphs_from_buffer function.
CVE-2024-4657 1 Talentsoftware 1 Bap Automation 2026-04-15 N/A
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Talent Software BAP Automation allows Stored XSS.This issue affects BAP Automation: before 30840.
CVE-2019-17082 1 Opentext 1 Accurev For Ldap Integration 2026-04-15 N/A
Insufficiently Protected Credentials vulnerability in OpenText™ AccuRev allows Authentication Bypass. When installed on a Linux or Solaris system the vulnerability could allow anyone who knows a valid AccuRev username can use the AccuRev client to login and gain access to AccuRev source control without knowing the user’s password. This issue affects AccuRev: 2017.1.
CVE-2024-56333 2026-04-15 N/A
Onyxia is a web app that aims at being the glue between multiple open source backend technologies to provide a state of art working environment for data scientists. This critical vulnerability allows authenticated users to remotely execute code within the Onyxia-API, leading to potential consequences such as unauthorized access to other user environments and denial of service attacks. This issue has been patched in api versions 4.2.0, 3.1.1, and 2.8.2. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-44087 1 Siemens 1 Automation License Manager 2026-04-15 8.6 High
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification.
CVE-2018-25128 2026-04-15 8.2 High
SOCA Access Control System 180612 contains multiple SQL injection vulnerabilities that allow attackers to manipulate database queries through unvalidated POST parameters. Attackers can bypass authentication, retrieve password hashes, and gain administrative access with full system privileges by exploiting injection flaws in Login.php and Card_Edit_GetJson.php.
CVE-2024-45032 1 Siemens 2 Industrial Edge Management Pro, Industrial Edge Management Virtual 2026-04-15 10 Critical
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
CVE-2018-25134 1 Synaccess 2 Netbooter Np-02x, Netbooter Np-08x 2026-04-15 9.8 Critical
Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management.
CVE-2018-25135 1 Anviz 1 Crosschex 2026-04-15 9.8 Critical
Anviz AIM CrossChex Standard 4.3.6.0 contains a CSV injection vulnerability that allows attackers to execute commands by inserting malicious formulas in user import fields. Attackers can craft payloads in fields like 'Name', 'Gender', or 'Position' to trigger Excel macro execution when importing user data.
CVE-2024-45367 1 Optigo 1 Ons-s8 Firmware 2026-04-15 9.1 Critical
The web server for ONS-S8 - Spectra Aggregation Switch includes an incomplete authentication process, which can lead to an attacker authenticating without a password.
CVE-2024-45480 2026-04-15 N/A
An improper control of generation of code ('Code Injection') vulnerability in the AprolCreateReport component of B&R APROL <4.4-00P5 may allow an unauthenticated network-based attacker to read files from the local system.
CVE-2024-56198 2026-04-15 N/A
path-sanitizer is a simple lightweight npm package for sanitizing paths to prevent Path Traversal. Prior to 3.1.0, the filters can be bypassed using .=%5c which results in a path traversal. This vulnerability is fixed in 3.1.0.
CVE-2025-8857 2026-04-15 9.8 Critical
Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).