| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An attacker could inject commands to delete files and/or delete the contents of a file on CX-Supervisor (Versions 3.42 and prior) through a specially crafted project file. |
| In Geutebrueck GmbH E2 Camera Series versions prior to 1.12.0.25 the DDNS configuration (in the Network Configuration panel) is vulnerable to an OS system command injection as root. |
| OSIsoft PI Vision, versions PI Vision 2017, and PI Vision 2017 R2, The application contains a cross-site scripting vulnerability where displays that reference AF elements and attributes containing JavaScript are affected. This vulnerability requires the ability of authorized AF users to store JavaScript in AF elements and attributes. |
| A denial of service vulnerability exists in Jenkins 2.137 and earlier, 2.121.2 and earlier in BasicAuthenticationFilter.java, BasicHeaderApiTokenAuthenticator.java that allows attackers to create ephemeral in-memory user records by attempting to log in using invalid credentials. |
| A cross-site scripting vulnerability exists in Jenkins Shelve Project Plugin 1.5 and earlier in ShelveProjectAction/index.jelly, ShelvedProjectsAction/index.jelly that allows attackers with Job/Configure permission to define JavaScript that would be executed in another user's browser when that other user performs some UI actions. |
| MathJax version prior to version 2.7.4 contains a Cross Site Scripting (XSS) vulnerability in the \unicode{} macro that can result in Potentially untrusted Javascript running within a web browser. This attack appear to be exploitable via The victim must view a page where untrusted content is processed using Mathjax. This vulnerability appears to have been fixed in 2.7.4 and later. |
| Gleezcms Gleez Cms version 1.3.0 contains a Cross Site Scripting (XSS) vulnerability in Profile page that can result in Inject arbitrary web script or HTML via the profile page editor. This attack appear to be exploitable via The victim must navigate to the attacker's profile page. |
| Pydio version 8.2.0 and earlier contains a Cross Site Scripting (XSS) vulnerability in ./core/vendor/meenie/javascript-packer/example-inline.php line 48; ./core/vendor/dapphp/securimage/examples/test.mysql.static.php lines: 114,118 that can result in an unauthenticated remote attacker manipulating the web client via XSS code injection. This attack appear to be exploitable via the victim openning a specially crafted URL. This vulnerability appears to have been fixed in version 8.2.1. |
| October CMS version prior to build 437 contains a Cross Site Scripting (XSS) vulnerability in the Media module and create folder functionality that can result in an Authenticated user with media module permission creating arbitrary folder name with XSS content. This attack appear to be exploitable via an Authenticated user with media module permission who can create arbitrary folder name (XSS). This vulnerability appears to have been fixed in build 437. |
| A cross-site scripting vulnerability exists in Jenkins 2.132 and earlier, 2.121.1 and earlier in the Stapler web framework's org/kohsuke/stapler/Stapler.java that allows attackers with the ability to control the existence of some URLs in Jenkins to define JavaScript that would be executed in another user's browser when that other user views HTTP 404 error pages while Stapler debug mode is enabled. |
| A cross-site scripting vulnerability exists in Jenkins 2.132 and earlier, 2.121.1 and earlier in BuildTimelineWidget.java, BuildTimelineWidget/control.jelly that allows attackers with Job/Configure permission to define JavaScript that would be executed in another user's browser when that other user performs some UI actions. |
| WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack. |
| LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges. |
| Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser. |
| LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server. |
| Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application. |
| LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server. |
| Reflected cross-site scripting (non-persistent) in SCADA WebServer (Versions prior to 2.03.0001) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser. |
| LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution. |
| Tridium Niagara Enterprise Security 2.3u1, all versions prior to 2.3.118.6, Niagara AX 3.8u4, all versions prior to 3.8.401.1, Niagara 4.4u2, all versions prior to 4.4.93.40.2, and Niagara 4.6, all versions prior to 4.6.96.28.4 a cross-site scripting vulnerability has been identified that may allow a remote attacker to inject code to some web pages affecting confidentiality. |