CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
plays_service.exe in the plays.tv service before 1.27.7.0, as distributed in AMD driver-installation packages and Gaming Evolved products, contains an HTTP message parsing function that takes a user-defined path and writes non-user controlled data as SYSTEM to the file when the extract_files parameter is used. This occurs without properly authenticating the user. |
plays_service.exe in the plays.tv service before 1.27.7.0, as distributed in AMD driver-installation packages and Gaming Evolved products, executes code at a user-defined (local or SMB) path as SYSTEM when the execute_installer parameter is used in an HTTP message. This occurs without properly authenticating the user. |
It was discovered that the Unitrends Backup (UB) before 10.1.0 user interface was exposed to an authentication bypass, which then could allow an unauthenticated user to inject arbitrary commands into its /api/hosts parameters using backquotes. |
Authentication bypass in Hanwha Techwin Smartcams |
Unsecured way of firmware update in Hanwha Techwin Smartcams |
A flaw in the profile section of Online Voting System 1.0 allows an unauthenticated user to set an arbitrary password for other accounts. |
In Silex SX-500 all versions and GE MobileLink(GEH-500) version 1.54 and prior, authentication is not verified when making certain POST requests, which may allow attackers to modify system settings. |
The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remote and local access, aka a "Use of Password Hash Instead of Password for Authentication" issue. This is exploitable by an attacker who discovers a hash value in the rainmachine-settings.sqlite file. |
An issue was discovered in Extreme Networks ExtremeWireless WiNG 5.x before 5.8.6.9 and 5.9.x before 5.9.1.3. There is No Authentication for the AeroScout Service via a crafted UDP packet. |
To provide fine-grained controls over the ability to use Dynamic DNS (DDNS) to update records in a zone, BIND 9 provides a feature called update-policy. Various rules can be configured to limit the types of updates that can be performed by a client, depending on the key used when sending the update request. Unfortunately, some rule types were not initially documented, and when documentation for them was added to the Administrator Reference Manual (ARM) in change #3112, the language that was added to the ARM at that time incorrectly described the behavior of two rule types, krb5-subdomain and ms-subdomain. This incorrect documentation could mislead operators into believing that policies they had configured were more restrictive than they actually were. This affects BIND versions prior to BIND 9.11.5 and BIND 9.12.3. |
Change #4777 (introduced in October 2017) introduced an unforeseen issue in releases which were issued after that date, affecting which clients are permitted to make recursive queries to a BIND nameserver. The intended (and documented) behavior is that if an operator has not specified a value for the "allow-recursion" setting, it SHOULD default to one of the following: none, if "recursion no;" is set in named.conf; a value inherited from the "allow-query-cache" or "allow-query" settings IF "recursion yes;" (the default for that setting) AND match lists are explicitly set for "allow-query-cache" or "allow-query" (see the BIND9 Administrative Reference Manual section 6.2 for more details); or the intended default of "allow-recursion {localhost; localnets;};" if "recursion yes;" is in effect and no values are explicitly set for "allow-query-cache" or "allow-query". However, because of the regression introduced by change #4777, it is possible when "recursion yes;" is in effect and no match list values are provided for "allow-query-cache" or "allow-query" for the setting of "allow-recursion" to inherit a setting of all hosts from the "allow-query" setting default, improperly permitting recursion to all clients. Affects BIND 9.9.12, 9.10.7, 9.11.3, 9.12.0->9.12.1-P2, the development release 9.13.0, and also releases 9.9.12-S1, 9.10.7-S1, 9.11.3-S1, and 9.11.3-S2 from BIND 9 Supported Preview Edition. |
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. |
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions. |
In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code. |
The Quest Kace K1000 Appliance, versions prior to 9.0.270, allows a remote attacker to exploit the misconfigured Cross-Origin Resource Sharing (CORS) mechanism. An unauthenticated, remote attacker could exploit this vulnerability to perform sensitive actions such as adding a new administrator account or changing the appliance’s settings. A malicious internal user could also gain administrator privileges of this appliance and use it to visit a malicious link that exploits this vulnerability. This could cause the application to perform sensitive actions such as adding a new administrator account or changing the appliance’s settings. An unauthenticated, remote attacker could add an administrator-level account or change the appliance's settings. |
Imperva SecureSphere gateway (GW) running v13, for both pre-First Time Login or post-First Time Login (FTL), if the attacker knows the basic authentication passwords, the GW may be vulnerable to RCE through specially crafted requests, from the web access management interface. |
Wizkunde SAMLBase may incorrectly utilize the results of XML DOM traversal and canonicalization APIs in such a way that an attacker may be able to manipulate the SAML data without invalidating the cryptographic signature, allowing the attack to potentially bypass authentication to SAML service providers. |
Some Navarino Infinity functions, up to version 2.2, placed in the URL can bypass any authentication mechanism leading to an information leak. |
ZUUSE BEIMS ContractorWeb .NET 5.18.0.0 allows access to various /UserManagement/ privileged modules without authenticating the user; an attacker can misuse these functionalities to perform unauthorized actions, as demonstrated by Edit User Details. |
Command injection vulnerability in Citrix NetScaler ADC and NetScaler Gateway 11.0 before build 70.16, 11.1 before build 55.13, and 12.0 before build 53.13; and the NetScaler Load Balancing instance distributed with NetScaler SD-WAN/CloudBridge 4000, 4100, 5000 and 5100 WAN Optimization Edition 9.3.0 allows remote attackers to execute a system command or read arbitrary files via an SSH login prompt. |