Search vulnerabilities

Results 2,380

CVE-2015-6675

Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.

CVSS 2.0 · 4.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2016-3963

Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443.

CVSS 3.0 · 5.3 Medium EPSS 8.2% KEV · Not listed
Vendors
Products
CVE-2016-7090

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.

CVSS 3.0 · 4.0 Medium EPSS 1.9% KEV · Not listed
Vendors
CVE-2016-5874

Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets.

CVSS 3.0 · 7.5 High EPSS 3.5% KEV · Not listed
Vendors
CVE-2014-4683

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.

CVSS 2.0 · 4.9 Medium EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.

CVSS 3.0 · 5.3 Medium EPSS 2.7% KEV · Not listed
Vendors
CVE-2016-8673

A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server at port 80/TCP or port 443/TCP of the affected devices could allow remote attackers to perform actions with the permissions of an authenticated user, provided the targeted user has an active session and is induced to trigger the malicious request.

CVSS 3.0 · 8.8 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2016-6486

Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2015-1594

Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows local users to gain privileges via a Trojan horse application file.

CVSS 2.0 · 6.9 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2016-6204

Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.

CVSS 3.0 · 6.1 Medium EPSS 1.6% KEV · Not listed
Vendors
CVE-2016-4785

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.

CVSS 3.0 · 5.3 Medium EPSS 2.7% KEV · Not listed
Vendors
CVE-2015-5537

The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulnerability than CVE-2014-3566.

CVSS 2.0 · 4.3 Medium EPSS 1.1% KEV · Not listed
Vendors
CVE-2015-3610

The Siemens HomeControl for Room Automation application before 2.0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information or modify data via a crafted certificate.

CVSS 2.0 · 5.4 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2015-5386

Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests.

CVSS 2.0 · 9.3 Critical EPSS 3.2% KEV · Not listed
Vendors
CVE-2015-1601

Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.

CVSS 2.0 · 6.8 Medium EPSS 1.4% KEV · Not listed
Vendors
Products
CVE-2015-4174

Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.

CVSS 2.0 · 4.3 Medium EPSS 2.5% KEV · Not listed
Vendors
CVE-2016-7959

Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack.

CVSS 3.0 · 4.7 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2016-7112

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.

CVSS 3.0 · 9.8 Critical EPSS 2.9% KEV · Not listed
Vendors