Filtered by vendor Siemens
Subscriptions
Total
1927 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-25667 | 1 Siemens | 30 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 27 more | 2024-11-21 | 8.8 High |
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active. | ||||
CVE-2021-25666 | 1 Siemens | 4 Scalance W740, Scalance W740 Firmware, Scalance W780 and 1 more | 2024-11-21 | 4.3 Medium |
A vulnerability has been identified in SCALANCE W780 and W740 (IEEE 802.11n) family (All versions < V6.3). Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time. | ||||
CVE-2021-25665 | 1 Siemens | 1 Simcenter Star-ccm\+ | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700) | ||||
CVE-2021-25664 | 1 Siemens | 5 Capital Vstar, Nucleus Net, Nucleus Readystart V3 and 2 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values. | ||||
CVE-2021-25663 | 1 Siemens | 4 Capital Vstar, Nucleus Net, Nucleus Readystart and 1 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values. | ||||
CVE-2021-25662 | 1 Siemens | 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition. | ||||
CVE-2021-25661 | 1 Siemens | 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition. | ||||
CVE-2021-25660 | 1 Siemens | 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. | ||||
CVE-2021-25659 | 1 Siemens | 1 Automation License Manager | 2024-11-21 | 7.5 High |
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system. | ||||
CVE-2021-25220 | 6 Fedoraproject, Isc, Juniper and 3 more | 50 Fedora, Bind, Junos and 47 more | 2024-11-21 | 6.8 Medium |
BIND 9.11.0 -> 9.11.36 9.12.0 -> 9.16.26 9.17.0 -> 9.18.0 BIND Supported Preview Editions: 9.11.4-S1 -> 9.11.36-S1 9.16.8-S1 -> 9.16.26-S1 Versions of BIND 9 earlier than those shown - back to 9.1.0, including Supported Preview Editions - are also believed to be affected but have not been tested as they are EOL. The cache could become poisoned with incorrect records leading to queries being made to the wrong servers, which might also result in false information being returned to clients. | ||||
CVE-2021-25219 | 7 Debian, Fedoraproject, Isc and 4 more | 24 Debian Linux, Fedora, Bind and 21 more | 2024-11-21 | 5.3 Medium |
In BIND 9.3.0 -> 9.11.35, 9.12.0 -> 9.16.21, and versions 9.9.3-S1 -> 9.11.35-S1 and 9.16.8-S1 -> 9.16.21-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.18 of the BIND 9.17 development branch, exploitation of broken authoritative servers using a flaw in response processing can cause degradation in BIND resolver performance. The way the lame cache is currently designed makes it possible for its internal data structures to grow almost infinitely, which may cause significant delays in client query processing. | ||||
CVE-2021-25217 | 6 Debian, Fedoraproject, Isc and 3 more | 33 Debian Linux, Fedora, Dhcp and 30 more | 2024-11-21 | 7.4 High |
In ISC DHCP 4.1-ESV-R1 -> 4.1-ESV-R16, ISC DHCP 4.4.0 -> 4.4.2 (Other branches of ISC DHCP (i.e., releases in the 4.0.x series or lower and releases in the 4.3.x series) are beyond their End-of-Life (EOL) and no longer supported by ISC. From inspection it is clear that the defect is also present in releases from those series, but they have not been officially tested for the vulnerability), The outcome of encountering the defect while reading a lease that will trigger it varies, according to: the component being affected (i.e., dhclient or dhcpd) whether the package was built as a 32-bit or 64-bit binary whether the compiler flag -fstack-protection-strong was used when compiling In dhclient, ISC has not successfully reproduced the error on a 64-bit system. However, on a 32-bit system it is possible to cause dhclient to crash when reading an improper lease, which could cause network connectivity problems for an affected system due to the absence of a running DHCP client process. In dhcpd, when run in DHCPv4 or DHCPv6 mode: if the dhcpd server binary was built for a 32-bit architecture AND the -fstack-protection-strong flag was specified to the compiler, dhcpd may exit while parsing a lease file containing an objectionable lease, resulting in lack of service to clients. Additionally, the offending lease and the lease immediately following it in the lease database may be improperly deleted. if the dhcpd server binary was built for a 64-bit architecture OR if the -fstack-protection-strong compiler flag was NOT specified, the crash will not occur, but it is possible for the offending lease and the lease which immediately followed it to be improperly deleted. | ||||
CVE-2021-25216 | 4 Debian, Isc, Netapp and 1 more | 23 Debian Linux, Bind, Active Iq Unified Manager and 20 more | 2024-11-21 | 8.1 High |
In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting values for the tkey-gssapi-keytab or tkey-gssapi-credential configuration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. For servers that meet these conditions, the ISC SPNEGO implementation is vulnerable to various attacks, depending on the CPU architecture for which BIND was built: For named binaries compiled for 64-bit platforms, this flaw can be used to trigger a buffer over-read, leading to a server crash. For named binaries compiled for 32-bit platforms, this flaw can be used to trigger a server crash due to a buffer overflow and possibly also to achieve remote code execution. We have determined that standard SPNEGO implementations are available in the MIT and Heimdal Kerberos libraries, which support a broad range of operating systems, rendering the ISC implementation unnecessary and obsolete. Therefore, to reduce the attack surface for BIND users, we will be removing the ISC SPNEGO implementation in the April releases of BIND 9.11 and 9.16 (it had already been dropped from BIND 9.17). We would not normally remove something from a stable ESV (Extended Support Version) of BIND, but since system libraries can replace the ISC SPNEGO implementation, we have made an exception in this case for reasons of stability and security. | ||||
CVE-2021-25215 | 7 Debian, Fedoraproject, Isc and 4 more | 31 Debian Linux, Fedora, Bind and 28 more | 2024-11-21 | 7.5 High |
In BIND 9.0.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a query for a record triggering the flaw described above, the named process will terminate due to a failed assertion check. The vulnerability affects all currently maintained BIND 9 branches (9.11, 9.11-S, 9.16, 9.16-S, 9.17) as well as all other versions of BIND 9. | ||||
CVE-2021-25214 | 6 Debian, Fedoraproject, Isc and 3 more | 25 Debian Linux, Fedora, Bind and 22 more | 2024-11-21 | 6.5 Medium |
In BIND 9.8.5 -> 9.8.8, 9.9.3 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND 9 Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a malformed IXFR triggering the flaw described above, the named process will terminate due to a failed assertion the next time the transferred secondary zone is refreshed. | ||||
CVE-2021-25178 | 2 Opendesign, Siemens | 4 Drawings Software Development Kit, Comos, Jt2go and 1 more | 2024-11-21 | 7.8 High |
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. | ||||
CVE-2021-25177 | 2 Opendesign, Siemens | 4 Drawings Software Development Kit, Comos, Jt2go and 1 more | 2024-11-21 | 7.8 High |
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). | ||||
CVE-2021-25176 | 2 Opendesign, Siemens | 4 Drawings Software Development Kit, Comos, Jt2go and 1 more | 2024-11-21 | 7.8 High |
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). | ||||
CVE-2021-25175 | 2 Opendesign, Siemens | 4 Drawings Software Development Kit, Comos, Jt2go and 1 more | 2024-11-21 | 7.8 High |
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). | ||||
CVE-2021-25174 | 2 Opendesign, Siemens | 4 Drawings Software Development Kit, Comos, Jt2go and 1 more | 2024-11-21 | 7.8 High |
An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). |