CVE-2020-24672 1 Abb 1 Base Software 2024-11-21 9.8 Critical
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
CVE-2020-11420 2 Abb, Generex 4 Cs141, Cs141 Firmware, Cs141 and 1 more 2024-11-21 6.5 Medium
UPS Adapter CS141 before 1.90 allows Directory Traversal. An attacker with Admin or Engineer login credentials could exploit the vulnerability by manipulating variables that reference files and by doing this achieve access to files and directories outside the web root folder. An attacker may access arbitrary files and directories stored in the file system, but integrity of the files are not jeopardized as attacker have read access rights only.
CVE-2020-10288 2 Abb, Windriver 4 Irb140, Irc5, Robotware and 1 more 2024-11-21 9.8 Critical
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
CVE-2020-10287 1 Abb 4 Irb140, Irb140 Firmware, Irc5 and 1 more 2024-11-21 9.8 Critical
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
CVE-2019-7232 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 8.8 High
The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. The Host header value overflows a buffer and overwrites a Structured Exception Handler (SEH) address. An unauthenticated attacker can submit a Host header value of 2047 bytes or more to overflow the buffer and overwrite the SEH address, which can then be leveraged to execute attacker-controlled code on the server.
CVE-2019-7231 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 5.7 Medium
The ABB IDAL FTP server is vulnerable to a buffer overflow when a long string is sent by an authenticated attacker. This overflow is handled, but terminates the process. An authenticated attacker can send a FTP command string of 472 bytes or more to overflow a buffer, causing an exception that terminates the server.
CVE-2019-7230 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 8.8 High
The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Attempting to authenticate with the username %s%p%x%d will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.
CVE-2019-7229 1 Abb 15 Board Support Package Un31, Cp620, Cp620-web and 12 more 2024-11-21 8.3 High
The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilization of USB/SD Card to flash the device" and "Remote provisioning process via ABB Panel Builder 600 over FTP." Neither of these transmission methods implements any form of encryption or authenticity checks against the new firmware HMI software binary files.
CVE-2019-7228 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 8.8 High
The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Attempting to authenticate with the username %25s%25p%25x%25n will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.
CVE-2019-7227 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 7.3 High
In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker.
CVE-2019-7226 1 Abb 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware 2024-11-21 8.8 High
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
CVE-2019-7225 1 Abb 32 Cp620, Cp620-web, Cp620-web Firmware and 29 more 2024-11-21 8.8 High
The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 password for the IdalMaster account, and the exor password for the exor account. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials. An attacker can use these credentials to login to ABB HMI to read/write HMI configuration files and also to reset the device. This affects ABB CP635 HMI, CP600 HMIClient, Panel Builder 600, IDAL FTP server, IDAL HTTP server, and multiple other HMI components.
CVE-2019-19107 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2024-11-21 6.2 Medium
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
CVE-2019-19106 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2024-11-21 9.1 Critical
Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings.
CVE-2019-19105 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2024-11-21 6.2 Medium
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
CVE-2019-19104 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2024-11-21 9.1 Critical
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
CVE-2019-18997 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 4.3 Medium
The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access.
CVE-2019-18996 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 7.1 High
Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.
CVE-2019-18995 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 4.3 Medium
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.
CVE-2019-18994 1 Abb 1 Pb610 Panel Builder 600 2024-11-21 3.9 Low
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.