| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Netgear WNR854T 1.5.2 (North America) is vulnerable to Command Injection. An attacker can send a specially crafted request to post.cgi, updating the nvram parameter get_email. After which, they can visit the send_log.cgi endpoint which uses the parameter in a system call to achieve command execution. |
| Netgear WNR854T 1.5.2 (North America) is vulnerable to Arbitrary command execution in cmd.cgi which allows for the execution of system commands via the web interface. |
| In Netgear WNR854T 1.5.2 (North America), the UPNP service is vulnerable to command injection in the function addmap_exec which parses the NewInternalClient parameter of the AddPortMapping SOAPAction into a system call without sanitation. An attacker can send a specially crafted SOAPAction request for AddPortMapping via the router's WANIPConn1 service to achieve arbitrary command execution. |
| GetSimple CMS CE 3.3.19 suffers from arbitrary code execution in the template editing function in the background management system, which can be used by an attacker to implement RCE. |
| An issue in CodeAstro Complaint Management System v.1.0 allows a remote attacker to escalate privileges via the mess-view.php component. |
| An issue was discovered in Artifex Ghostscript before 10.03.1. contrib/opvp/gdevopvp.c allows arbitrary code execution via a custom Driver library, exploitable via a crafted PostScript document. This occurs because the Driver parameter for opvp (and oprp) devices can have an arbitrary name for a dynamic library; this library is then loaded. |
| Cross Site Scripting vulnerability in php-lms/admin/?page=system_info in Computer Laboratory Management System using PHP and MySQL 1.0 allow remote attackers to inject arbitrary web script or HTML via the name, shortname parameters. |
| An issue in onethink v.1.1 allows a remote attacker to execute arbitrary code via a crafted script to the AddonsController.class.php component. |
| An issue was discovered in RWS WorldServer before 11.7.3. An authenticated, remote attacker can perform a ws-legacy/load_dtd?system_id= blind SSRF attack to deploy JSP code to the Apache Axis service running on the localhost interface, leading to command execution. |
| Wildix WMS 6 before 6.02.20221216, WMS 5 before 5.04.20221214, and WMS4 before 4.04.45396.23 allows Server-side request forgery (SSRF) via ZohoClient.php. |
| The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history. |
| The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services). |
| Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user. |
| The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. Affected controllers that are actively supported include MX207, MX213, MX220, MC206, MC212, MC220, and MH230 hardware controllers, and affected end-of-life controller include MC205, MC210, MH212, ME203, CS200, MP213, MP226, MPC240, MPC265, MPC270, MPC293, MPE270, and CPC210 hardware controllers. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticated person with physical access to the device reads and decrypts the password to conduct further attacks. |
|
Altair HyperView Player versions 2021.1.0.27 and prior are vulnerable to the use of uninitialized memory vulnerability during parsing of H3D files. A DWORD is extracted from an uninitialized buffer and, after sign extension, is used as an index into a stack variable to increment a counter leading to memory corruption.
|
|
Altair HyperView Player versions 2021.1.0.27 and prior are vulnerable to the use of uninitialized memory vulnerability during parsing of H3D files. A DWORD is extracted from an uninitialized buffer and, after sign extension, is used as an index into a stack variable to increment a counter leading to memory corruption.
|
| This vulnerability could allow an attacker to force the server to create and execute a web request granting access to backend APIs that are only accessible to the Mimosa MMP server, or request pages that could perform some actions themselves. The attacker could force the server into accessing routes on those cloud-hosting platforms, accessing secret keys, changing configurations, etc. Affecting MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1. |
| Simulation models for KUKA.Sim Pro version 3.1 are hosted by a server maintained by KUKA. When these devices request a model, the server transmits the model in plaintext. |
| A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system. |
| Philips Gemini PET/CT family software stores sensitive information in a removable media device that does not have built-in access control. |