| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Directus is a real-time API and App dashboard for managing SQL database content. Starting in version 9.12.0 and prior to version 11.9.0, Directus Flows with a manual trigger are not validating whether the user triggering the Flow has permissions to the items provided as payload to the Flow. Depending on what the Flow is set up to do this can lead to the Flow executing potential tasks on the attacker's behalf without authenticating. Bad actors could execute the manual trigger Flows without authentication, or access rights to the said collection(s) or item(s). Users with manual trigger Flows configured are impacted as these endpoints do not currently validate if the user has read access to `directus_flows` or to the relevant collection/items. The manual trigger Flows should have tighter security requirements as compared to webhook Flows where users are expected to perform do their own checks. Version 11.9.0 fixes the issue. As a workaround, implement permission checks for read access to Flows and read access to relevant collection/items. |
| An issue in KeeperChat IOS Application v.5.8.8 allows a physically proximate attacker to escalate privileges via the Biometric Authentication Module |
| An improper authentication in Fortinet FortiClientMac 7.0.11 through 7.2.4 allows attacker to gain improper access to MacOS via empty password. |
| In Apache Cassandra it is possible for a local attacker without access
to the Apache Cassandra process or configuration files to manipulate
the RMI registry to perform a man-in-the-middle attack and capture user
names and passwords used to access the JMX interface. The attacker can
then use these credentials to access the JMX interface and perform
unauthorized operations.
This is same vulnerability that CVE-2020-13946 was issued for, but the Java option was changed in JDK10.
This issue affects Apache Cassandra from 4.0.2 through 5.0.2 running Java 11.
Operators are recommended to upgrade to a release equal to or later than 4.0.15, 4.1.8, or 5.0.3 which fixes the issue. |
| A vulnerability was found in i-Drive i11 and i12 up to 20250227. It has been classified as problematic. Affected is an unknown function of the component Device Pairing. The manipulation leads to authentication bypass by primary weakness. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitability is told to be difficult. It was not possible to identify the current maintainer of the product. It must be assumed that the product is end-of-life. |
| There is an insufficient authentication vulnerability in some Huawei smart phone. An unauthenticated, local attacker can crafts software package to exploit this vulnerability. Due to insufficient verification, successful exploitation may impact the service. (Vulnerability ID: HWPSIRT-2019-12302)
This vulnerability has been assigned a Common Vulnerabilities and Exposures (CVE) ID: CVE-2020-9250. |
| Bypass vulnerability in the device management channel
Impact: Successful exploitation of this vulnerability may affect service confidentiality. |
| The Central application in i-GEN opLYNX before 2.01.9 allows remote attackers to bypass authentication via vectors involving the disabling of browser JavaScript support. |
| These Sinapsi devices
do not check if users that visit pages within the device have properly
authenticated. By directly visiting the pages within the device,
attackers can gain unauthorized access with administrative privileges. |
| Windows Netlogon Elevation of Privilege Vulnerability |
| Improper authentication in Microsoft Dataverse allows an authorized attacker to elevate privileges over a network. |
| An issue was discovered on COROS PACE 3 devices through 3.0808.0. It identifies itself as a device without input or output capabilities, which results in the use of the Just Works pairing method. This method does not implement any authentication, which therefore allows machine-in-the-middle attacks. Furthermore, this lack of authentication allows attackers to interact with the device via BLE without requiring prior authorization. |
| An issue was discovered on COROS PACE 3 devices through 3.0808.0. It starts advertising if no device is connected via Bluetooth. This allows an attacker to connect with the device via BLE if no other device is connected. While connected, none of the BLE services and characteristics of the device require any authentication or security level. Therefore, any characteristic, depending on their mode of operation (read/write/notify), can be used by the connected attacker. This allows, for example, configuring the device, sending notifications, resetting the device to factory settings, or installing software. |
| A vulnerability in the Netgear DGN2200 router with firmware version v1.0.0.46 and earlier permits unauthorized individuals to bypass the authentication. When adding "?x=1.gif" to the the requested url, it will be recognized as passing the authentication. |
| A vulnerability, which was classified as critical, was found in TOTOLINK T6 4.1.5cu.748_B20211015. This affects the function Form_Login of the file /formLoginAuth.htm. The manipulation of the argument authCode/goURL leads to missing authentication. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. |
| Veeam Backup Enterprise Manager allows unauthenticated users to log in as any user to enterprise manager web interface. |
| Audiobookshelf is a self-hosted audiobook and podcast server. Starting in version 2.17.0 and prior to version 2.19.1, a flaw in the authentication bypass logic allows unauthenticated requests to match certain unanchored regex patterns in the URL. Attackers can craft URLs containing substrings like "/api/items/1/cover" in a query parameter (?r=/api/items/1/cover) to partially bypass authentication or trigger server crashes under certain routes. This could lead to information disclosure of otherwise protected data and, in some cases, a complete denial of service (server crash) if downstream code expects an authenticated user object. Version 2.19.1 contains a patch for the issue. |
| The Festo CECX-X-C1 Modular Master Controller with CoDeSys and CECX-X-M1 Modular Controller with CoDeSys and SoftMotion do not require authentication for connections to certain TCP ports, which allows remote attackers to (1) modify the configuration via a request to the debug service on port 4000 or (2) delete log entries via a request to the log service on port 4001. |
| The Festo CECX-X-C1 Modular Master Controller with CoDeSys and CECX-X-M1
Modular Controller with CoDeSys and SoftMotion provide an undocumented
access method involving the FTP protocol, which could allow a remote attacker to execute arbitrary code or cause a denial of service (application
crash) via unspecified vectors. |
| ControlID iDSecure On-premises versions 4.7.48.0 and prior are vulnerable to an improper authentication vulnerability which could allow an attacker to bypass authentication and gain permissions in the product. |