| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Hyper-V in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows guest OS users to execute arbitrary code on the host OS via a crafted application, aka "Hyper-V Remote Code Execution Vulnerability." This vulnerability is different from that described in CVE-2017-0075. |
| Insufficient Policy Enforcement in Omnibox in Google Chrome prior to 59.0.3071.115 for Mac allowed a remote attacker to perform domain spoofing via a crafted domain name containing a U+0620 character, aka Apple rdar problem 32458012. |
| Insufficient policy enforcement during navigation between different schemes in Google Chrome prior to 60.0.3112.78 for Android allowed a remote attacker to perform cross origin content download via a crafted HTML page, related to intents. |
| Insufficient validation of untrusted input in Skia in Google Chrome prior to 60.0.3112.78 for Linux allowed a remote attacker to perform an out of bounds memory read via a crafted HTML page. |
| Insufficient validation of untrusted input in PPAPI Plugins in Google Chrome prior to 60.0.3112.78 for Mac allowed a remote attacker to potentially gain privilege elevation via a crafted HTML page. |
| Uniscribe in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, and Windows 7 SP1 allows remote attackers to obtain sensitive information from process memory via a crafted web site, aka "Uniscribe Information Disclosure Vulnerability." CVE-2017-0085, CVE-2017-0091, CVE-2017-0092, CVE-2017-0111, CVE-2017-0112, CVE-2017-0113, CVE-2017-0114, CVE-2017-0115, CVE-2017-0116, CVE-2017-0117, CVE-2017-0118, CVE-2017-0119, CVE-2017-0120, CVE-2017-0121, CVE-2017-0122, CVE-2017-0123, CVE-2017-0124, CVE-2017-0125, CVE-2017-0127, and CVE-2017-0128. |
| A vulnerability in the Cisco Finesse Notification Service for Cisco Unified Contact Center Enterprise (UCCE) 11.5(1) and 11.6(1) could allow an unauthenticated, remote attacker to retrieve information from agents using the Finesse Desktop. The vulnerability is due to the existence of a user account that has an undocumented, hard-coded password. An attacker could exploit this vulnerability by using the hard-coded credentials to subscribe to the Finesse Notification Service, which would allow the attacker to receive notifications when an agent signs in or out of the Finesse Desktop, when information about an agent changes, or when an agent's state changes. Cisco Bug IDs: CSCvc08314. |
| OSRAM SYLVANIA Osram Lightify Pro before 2016-07-26 allows attackers to obtain sensitive information by reading screenshots under /private/var/mobile/Containers/Data/Application. |
| A information disclosure vulnerability in the Android media framework (libhevc). Product: Android. Versions: 5.0.2, 5.1.1, 6.0, 6.0.1, 7.0, 7.1.1, 7.1.2. Android ID: A-37712181. |
| Uniscribe in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, and Windows 7 SP1 allows remote attackers to obtain sensitive information from process memory via a crafted web site, aka "Uniscribe Information Disclosure Vulnerability." CVE-2017-0085, CVE-2017-0091, CVE-2017-0092, CVE-2017-0112, CVE-2017-0113, CVE-2017-0114, CVE-2017-0115, CVE-2017-0116, CVE-2017-0117, CVE-2017-0118, CVE-2017-0119, CVE-2017-0120, CVE-2017-0121, CVE-2017-0122, CVE-2017-0123, CVE-2017-0124, CVE-2017-0125, CVE-2017-0126, CVE-2017-0127, and CVE-2017-0128. |
| Uniscribe in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, and Windows 7 SP1 allows remote attackers to obtain sensitive information from process memory via a crafted web site, aka "Uniscribe Information Disclosure Vulnerability." CVE-2017-0085, CVE-2017-0091, CVE-2017-0092, CVE-2017-0111, CVE-2017-0113, CVE-2017-0114, CVE-2017-0115, CVE-2017-0116, CVE-2017-0117, CVE-2017-0118, CVE-2017-0119, CVE-2017-0120, CVE-2017-0121, CVE-2017-0122, CVE-2017-0123, CVE-2017-0124, CVE-2017-0125, CVE-2017-0126, CVE-2017-0127, and CVE-2017-0128. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device. |
| Uniscribe in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, and Windows 7 SP1 allows remote attackers to obtain sensitive information from process memory via a crafted web site, aka "Uniscribe Information Disclosure Vulnerability." CVE-2017-0085, CVE-2017-0091, CVE-2017-0092, CVE-2017-0111, CVE-2017-0112, CVE-2017-0113, CVE-2017-0114, CVE-2017-0116, CVE-2017-0117, CVE-2017-0118, CVE-2017-0119, CVE-2017-0120, CVE-2017-0121, CVE-2017-0122, CVE-2017-0123, CVE-2017-0124, CVE-2017-0125, CVE-2017-0126, CVE-2017-0127, and CVE-2017-0128. |
| A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow remote denial of service. |
| Uniscribe in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, and Windows 7 SP1 allows remote attackers to obtain sensitive information from process memory via a crafted web site, aka "Uniscribe Information Disclosure Vulnerability." CVE-2017-0085, CVE-2017-0091, CVE-2017-0092, CVE-2017-0111, CVE-2017-0112, CVE-2017-0113, CVE-2017-0114, CVE-2017-0115, CVE-2017-0117, CVE-2017-0118, CVE-2017-0119, CVE-2017-0120, CVE-2017-0121, CVE-2017-0122, CVE-2017-0123, CVE-2017-0124, CVE-2017-0125, CVE-2017-0126, CVE-2017-0127, and CVE-2017-0128. |
| The kernel in Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows an authenticated attacker to obtain information via a specially crafted application. aka "Windows Kernel Information Disclosure Vulnerability," a different vulnerability than CVE-2017-8491, CVE-2017-8490, CVE-2017-8489, CVE-2017-8488, CVE-2017-8485, CVE-2017-8483, CVE-2017-8482, CVE-2017-8481, CVE-2017-8480, CVE-2017-8478, CVE-2017-8479, CVE-2017-8476, CVE-2017-8474, CVE-2017-8469, CVE-2017-8462, CVE-2017-0300, and CVE-2017-0297. |
| Installing a zero-permission Android application on certain Samsung Android devices with KK(4.4), L(5.0/5.1), and M(6.0) software can continually crash the system_server process in the Android OS. The zero-permission app will create an active install session for a separate app that it has embedded within it. The active install session of the embedded app is performed using the android.content.pm.PackageInstaller class and its nested classes in the Android API. The active install session will write the embedded APK file to the /data/app directory, but the app will not be installed since third-party applications cannot programmatically install apps. Samsung has modified AOSP in order to accelerate the parsing of APKs by introducing the com.android.server.pm.PackagePrefetcher class and its nested classes. These classes will parse the APKs present in the /data/app directory and other directories, even if the app is not actually installed. The embedded APK that was written to the /data/app directory via the active install session has a very large but valid AndroidManifest.xml file. Specifically, the AndroidManifest.xml file contains a very large string value for the name of a permission-tree that it declares. When system_server tries to parse the APK file of the embedded app from the active install session, it will crash due to an uncaught error (i.e., java.lang.OutOfMemoryError) or an uncaught exception (i.e., std::bad_alloc) because of memory constraints. The Samsung Android device will encounter a soft reboot due to a system_server crash, and this action will keep repeating since parsing the APKs in the /data/app directory as performed by the system_server process is part of the normal boot process. The Samsung ID is SVE-2016-6917. |
| QNAP QTS before 4.2.4 Build 20170313 allows local users to obtain sensitive Domain Administrator password information by reading data in an XOR format within the /etc/config/uLinux.conf configuration file. |
| An untrusted search path (aka DLL Preloading) vulnerability in the Cisco Immunet antimalware installer could allow an authenticated, local attacker to execute arbitrary code via DLL hijacking if a local user with administrative privileges executes the installer in the current working directory where a crafted DLL has been placed by an attacker. The vulnerability is due to incomplete input validation of path and file names of a DLL file before it is loaded. An attacker could exploit this vulnerability by creating a malicious DLL file and installing it in a specific system directory. A successful exploit could allow the attacker to execute commands on the underlying Microsoft Windows host with privileges equivalent to the SYSTEM account. An attacker would need valid user credentials to exploit this vulnerability. Cisco Bug IDs: CSCvf23928. |
| In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the SNMP read-only (RO) community string has access to sensitive information by OID reference. |