| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Ember ZNet stack’s packet buffer manager may read out of bound memory leading to an assert, causing a Denial of Service (DoS). |
| The DIOT SCADA with MQTT plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the plugin's 'diot' shortcode in all versions up to, and including, 1.0.5.1 due to insufficient input sanitization and output escaping on user supplied attributes. This makes it possible for authenticated attackers, with contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. |
| A path traversal vulnerability in Novakon P series allows to expose the root file system "/" and modify all files with root permissions. This way the system can also be compromized.This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build
2026.02.06 (commit d0f97fd9). |
| Improper privilege management vulnerability in Novakon P series allows attackers to gain root privileges if one service is compromized.This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build
2026.02.06 (commit d0f97fd9). |
| An information disclosure vulnerability in the SD-WAN feature of Palo Alto Networks PAN-OS® software enables an unauthorized user to view unencrypted data sent from the firewall through the SD-WAN interface. This requires the user to be able to intercept packets sent from the firewall.
Cloud NGFW and Prisma® Access are not affected by this vulnerability. |
| Unverified password change vulnerability in Janto, versions prior to r12. This could allow an unauthenticated attacker to change another user's password without knowing their current password. To exploit the vulnerability, the attacker must create a specific POST request and send it to the endpoint ‘/public/cgi/Gateway.php’. |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Artbees SellKit allows Relative Path Traversal.This issue affects SellKit: from n/a through 1.8.1. |
| Inclusion of Functionality from Untrusted Control Sphere vulnerability in HCL MyXalytics. v6.6
allows Loading third-party scripts without integrity checks or validation can allow external code run in the application's context, risking data exposure. |
| A vulnerability was identified in certain UniFi Talk devices where internal debugging functionality remained unintentionally enabled. This issue could allow an attacker with access to the UniFi Talk management network to invoke internal debug operations through the device API.
Affected Products:
UniFi Talk Touch (Version 1.21.16 and earlier)
UniFi Talk Touch Max (Version 2.21.22 and earlier)
UniFi Talk G3 Phones (Version 3.21.26 and earlier)
Mitigation:
Update the UniFi Talk Touch to Version 1.21.17 or later.
Update the UniFi Talk Touch Max to Version 2.21.23 or later.
Update the UniFi Talk G3 Phones to Version 3.21.27 or later. |
| Software installed and run as a non-privileged user may conduct ptrace system calls to issue writes to GPU origin read only memory. |
| All versions of the package private-ip are vulnerable to Server-Side Request Forgery (SSRF) where an attacker can provide an IP or hostname that resolves to a multicast IP address (224.0.0.0/4) which is not included as part of the private IP ranges in the package's source code. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| Improper Authentication vulnerability in TYPO3 Extension "Modules" codingms/modules.This issue affects Extension "Modules": before 4.3.11, from 5.0.0 before 5.7.4, from 6.0.0 before 6.4.2, from 7.0.0 before 7.5.5. |
| The wsc server uses a hard-coded certificate to check the authenticity of SOAP messages. An unauthenticated remote attacker can extract private keys from the Software of the affected devices. |
| A high privileged remote attacker can influence the parameters passed to the openssl command due to improper neutralization of special elements when adding a password protected self-signed certificate. |
| A low privileged remote attacker can upload arbitrary data masked as a png file to the affected device using the webserver API because only the file extension is verified. |
| A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. |
| The database for the web application is exposed without authentication, allowing an unauthenticated remote attacker to gain unauthorized access and potentially compromise it. |
| A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been declared as critical. This vulnerability affects the function sendCommand of the file runcmd.sh. The manipulation of the argument cmd leads to command injection. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The researcher highlights, that "[a]lthough this functionality is currently disabled due to server CGI configuration errors, it is essentially a 'time bomb' waiting to be activated". The vendor was contacted early about this disclosure but did not respond in any way. |
| Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission. |