Filtered by CWE-121
Total 2081 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-3910 2024-11-21 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3909 2024-11-21 8.8 High
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3907 2024-11-21 8.8 High
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3906 2024-11-21 8.8 High
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3905 2024-11-21 8.8 High
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3882 2024-11-21 8.8 High
A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3881 2024-11-21 8.8 High
A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3879 2024-11-21 8.8 High
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3878 2024-11-21 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3877 2024-11-21 8.8 High
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3876 2024-11-21 8.8 High
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3875 2024-11-21 8.8 High
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3874 2024-11-21 8.8 High
A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3286 2024-11-21 7.5 High
A buffer overflow vulnerability was identified in some Lenovo printers that could allow an unauthenticated user to trigger a device restart by sending a specially crafted web request.
CVE-2024-3079 1 Asus 7 Rt-ac68u Firmware, Rt-ac86u Firmware, Rt-ax57 Firmware and 4 more 2024-11-21 7.2 High
Certain models of ASUS routers have buffer overflow vulnerabilities, allowing remote attackers with administrative privileges to execute arbitrary commands on the device.
CVE-2024-3012 2024-11-21 8.8 High
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3011 2024-11-21 8.8 High
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3010 2024-11-21 8.8 High
A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3008 2024-11-21 8.8 High
A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3007 2024-11-21 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.