| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Subrion CMS 4.2.1 is vulnerable to SQL Injection via ia.core.mysqli.php. NOTE: this is disputed by multiple third parties because it refers to an HTTP request to a PHP file that only contains a class, without any mechanism for accepting external input, and the reportedly vulnerable method is not present in the file. |
| BACnet Stack before 1.3.2 has a decode function APDU buffer over-read in bacapp_decode_application_data in bacapp.c. |
| Weak JWT Secret vulnerabilitiy in EasyVirt DCScope <= 8.6.0 and CO2Scope <= 1.3.0 allows remote attackers to generate JWT for privilege escalation. The HMAC secret used for generating tokens is hardcoded as "somerandomaccesstoken". A weak HMAC secret poses a risk because attackers can use the predictable secret to create valid JSON Web Tokens (JWTs), allowing them access to important information and actions within the application. |
| JFinalCMS 1.0 is vulnerable to SQL Injection in rc/main/java/com/cms/entity/Content.java. The cause of the vulnerability is that the title parameter is controllable and is concatenated directly into filterSql without filtering. |
| Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| naga v0.14.0 was discovered to contain a stack overflow via the component /wgsl/parse/mod.rs. |
| Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet |
| Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting |
| Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand->FUN_0007dd20 with request /goform/SetNetControlList |
| Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set |
| Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in the function formDelDhcpRule with the request /goform/delDhcpRules/ |
| Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in the function formIPMacBindDel with the request /goform/delIpMacBind/ |
| Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in the function formSetDebugCfg with request /goform/setDebugCfg/ |
| Tenda W20E router V15.11.0.6 contains a stack overflow in the function formSetPortMapping with post request 'goform/setPortMapping/'. This vulnerability allows attackers to cause a Denial of Service (DoS) or Remote Code Execution (RCE) via the portMappingServer, portMappingProtocol, portMappingWan, porMappingtInternal, and portMappingExternal parameters. |
| Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set |
| Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat. |
| The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device. |
| an attacker with knowledge of user/pass of Grandstream GSD3710 in its 1.0.11.13 version, could overflow the stack since it doesn't check the param length before use the strcopy instruction. The explotation of this vulnerability may lead an attacker to execute a shell with full access. |
| This vulnerability exists in Tacitine Firewall, all versions of EN6200-PRIME QUAD-35 and EN6200-PRIME QUAD-100 between 19.1.1 to 22.20.1 (inclusive), due to improper control of code generation in the Tacitine Firewall web-based management interface. An unauthenticated remote attacker could exploit this vulnerability by sending a specially crafted http request on the targeted device. Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to execute arbitrary commands on the targeted device. |
| An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Hardcoded Credentials exist in the APK for Ports 9091 and 9092. The dashcam's Android application contains hardcoded credentials that allow unauthorized access to device settings through ports 9091 and 9092. These credentials, stored in cleartext, can be exploited by an attacker who gains access to the dashcam's network. |