Filtered by vendor Deltaww Subscriptions
Total 218 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-43457 1 Deltaww 1 Diaenergie 2024-08-03 8.8 High
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
CVE-2022-43452 1 Deltaww 1 Diaenergie 2024-08-03 8.8 High
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
CVE-2022-42139 1 Deltaww 2 Dvw-w02w2-e2, Dvw-w02w2-e2 Firmware 2024-08-03 8.8 High
Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.
CVE-2022-42140 1 Deltaww 2 Dx-2100-l1-cn, Dx-2100-l1-cn Firmware 2024-08-03 7.2 High
Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Command Injection via lform/net_diagnose.
CVE-2022-42141 1 Deltaww 2 Dx-2100-l1-cn, Dx-2100-l1-cn Firmware 2024-08-03 5.4 Medium
Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Cross Site Scripting (XSS) via lform/urlfilter.
CVE-2022-41778 1 Deltaww 1 Infrasuite Device Master 2024-08-03 9.8 Critical
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
CVE-2022-41779 1 Deltaww 1 Infrasuite Device Master 2024-08-03 8.8 High
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
CVE-2022-41775 1 Deltaww 1 Diaenergie 2024-08-03 8.8 High
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
CVE-2022-41772 1 Deltaww 1 Infrasuite Device Master 2024-08-03 9.8 Critical
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
CVE-2022-41776 1 Deltaww 1 Infrasuite Device Master 2024-08-03 7.5 High
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
CVE-2022-41644 1 Deltaww 1 Infrasuite Device Master 2024-08-03 8.8 High
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
CVE-2022-41688 1 Deltaww 1 Infrasuite Device Master 2024-08-03 9.8 Critical
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
CVE-2022-41657 1 Deltaww 1 Infrasuite Device Master 2024-08-03 9.8 Critical
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
CVE-2022-41629 1 Deltaww 1 Infrasuite Device Master 2024-08-03 7.5 High
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
CVE-2022-40202 1 Deltaww 1 Infrasuite Device Master 2024-08-03 9.8 Critical
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
CVE-2022-38142 1 Deltaww 1 Infrasuite Device Master 2024-08-03 9.8 Critical
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
CVE-2022-33005 1 Deltaww 1 Diaenergie 2024-08-03 6.1 Medium
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitrary web scripts via a crafted payload injected into the Name text field.
CVE-2022-4634 1 Deltaww 2 Cncsoft, Screeneditor 2024-08-03 7.8 High
All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.
CVE-2022-4616 1 Deltaww 2 Dx-3021l9, Dx-3021l9 Firmware 2024-08-03 7.2 High
The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis page. This vulnerability could allow a remote unauthenticated user to add files, delete files, and change file permissions.
CVE-2022-3214 1 Deltaww 1 Diaenergie 2024-08-03 9.8 Critical
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to  1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.