Total
5449 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2019-1966 | 1 Cisco | 8 Nx-os, Ucs 6248 Up Fabric Interconnect, Ucs 6296 Up Fabric Interconnect and 5 more | 2024-11-21 | 7.8 High |
A vulnerability in a specific CLI command within the local management (local-mgmt) context for Cisco UCS Fabric Interconnect Software could allow an authenticated, local attacker to gain elevated privileges as the root user on an affected device. The vulnerability is due to extraneous subcommand options present for a specific CLI command within the local-mgmt context. An attacker could exploit this vulnerability by authenticating to an affected device, entering the local-mgmt context, and issuing a specific CLI command and submitting user input. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device. The attacker would need to have valid user credentials for the device. | ||||
CVE-2019-1889 | 1 Cisco | 1 Application Policy Infrastructure Controller | 2024-11-21 | 7.2 High |
A vulnerability in the REST API for software device management in Cisco Application Policy Infrastructure Controller (APIC) Software could allow an authenticated, remote attacker to escalate privileges to root on an affected device. The vulnerability is due to incomplete validation and error checking for the file path when specific software is uploaded. An attacker could exploit this vulnerability by uploading malicious software using the REST API. A successful exploit could allow an attacker to escalate their privilege level to root. The attacker would need to have the administrator role on the device. | ||||
CVE-2019-1855 | 1 Cisco | 1 Jabber | 2024-11-21 | 7.3 High |
A vulnerability in the loading mechanism of specific dynamic link libraries in Cisco Jabber for Windows could allow an authenticated, local attacker to perform a DLL preloading attack. To exploit this vulnerability, the attacker would need to have valid credentials on the Windows system. The vulnerability is due to insufficient validation of the resources loaded by the application at run time. An attacker could exploit this vulnerability by crafting a malicious DLL file and placing it in a specific location on the targeted system. The malicious DLL file would execute when the Jabber application launches. A successful exploit could allow the attacker to execute arbitrary code on the target machine with the privileges of another user's account. | ||||
CVE-2019-1803 | 1 Cisco | 22 Nexus 9000 Series Application Centric Infrastructure, Nexus 93108tc-ex, Nexus 93120tx and 19 more | 2024-11-21 | 6.7 Medium |
A vulnerability in the filesystem management for the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an authenticated, local attacker with administrator rights to gain elevated privileges as the root user on an affected device. The vulnerability is due to overly permissive file permissions of specific system files. An attacker could exploit this vulnerability by authenticating to an affected device, creating a crafted command string, and writing this crafted string to a specific file location. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device. The attacker would need to have valid administrator credentials for the device. | ||||
CVE-2019-1723 | 1 Cisco | 1 Common Services Platform Collector | 2024-11-21 | 9.8 Critical |
A vulnerability in the Cisco Common Services Platform Collector (CSPC) could allow an unauthenticated, remote attacker to access an affected device by using an account that has a default, static password. This account does not have administrator privileges. The vulnerability exists because the affected software has a user account with a default, static password. An attacker could exploit this vulnerability by remotely connecting to the affected system using this account. A successful exploit could allow the attacker to log in to the CSPC using the default account. For Cisco CSPC 2.7.x, Cisco fixed this vulnerability in Release 2.7.4.6. For Cisco CSPC 2.8.x, Cisco fixed this vulnerability in Release 2.8.1.2. | ||||
CVE-2019-1682 | 1 Cisco | 1 Application Policy Infrastructure Controller | 2024-11-21 | 7.8 High |
A vulnerability in the FUSE filesystem functionality for Cisco Application Policy Infrastructure Controller (APIC) software could allow an authenticated, local attacker to escalate privileges to root on an affected device. The vulnerability is due to insufficient input validation for certain command strings issued on the CLI of the affected device. An attacker with write permissions for files within a readable folder on the device could alter certain definitions in the affected file. A successful exploit could allow an attacker to cause the underlying FUSE driver to execute said crafted commands, elevating the attacker's privileges to root on an affected device. | ||||
CVE-2019-1660 | 1 Cisco | 1 Telepresence Management Suite | 2024-11-21 | N/A |
A vulnerability in the Simple Object Access Protocol (SOAP) of Cisco TelePresence Management Suite (TMS) software could allow an unauthenticated, remote attacker to gain unauthorized access to an affected device. The vulnerability is due to a lack of proper access and authentication controls on the affected TMS software. An attacker could exploit this vulnerability by gaining access to internal, trusted networks to send crafted SOAP calls to the affected device. If successful, an exploit could allow the attacker to access system management tools. Under normal circumstances, this access should be prohibited. | ||||
CVE-2019-1648 | 1 Cisco | 12 Sd-wan, Vbond Orchestrator, Vedge 100 and 9 more | 2024-11-21 | 7.8 High |
A vulnerability in the user group configuration of the Cisco SD-WAN Solution could allow an authenticated, local attacker to gain elevated privileges on an affected device. The vulnerability is due to a failure to properly validate certain parameters included within the group configuration. An attacker could exploit this vulnerability by writing a crafted file to the directory where the user group configuration is located in the underlying operating system. A successful exploit could allow the attacker to gain root-level privileges and take full control of the device. | ||||
CVE-2019-1646 | 1 Cisco | 12 Sd-wan, Vbond Orchestrator, Vedge 100 and 9 more | 2024-11-21 | 7.8 High |
A vulnerability in the local CLI of the Cisco SD-WAN Solution could allow an authenticated, local attacker to escalate privileges and modify device configuration files. The vulnerability exists because user input is not properly sanitized for certain commands at the CLI. An attacker could exploit this vulnerability by sending crafted commands to the CLI of an affected device. A successful exploit could allow the attacker to establish an interactive session with elevated privileges. The attacker could then use the elevated privileges to further compromise the device or obtain additional configuration data from the device. | ||||
CVE-2019-1626 | 1 Cisco | 8 Sd-wan Firmware, Vedge-100, Vedge-1000 and 5 more | 2024-11-21 | 8.8 High |
A vulnerability in the vManage web-based UI (Web UI) of the Cisco SD-WAN Solution could allow an authenticated, remote attacker to gain elevated privileges on an affected vManage device. The vulnerability is due to a failure to properly authorize certain user actions in the device configuration. An attacker could exploit this vulnerability by logging in to the vManage Web UI and sending crafted HTTP requests to vManage. A successful exploit could allow attackers to gain elevated privileges and make changes to the configuration that they would not normally be authorized to make. | ||||
CVE-2019-1625 | 1 Cisco | 8 Sd-wan Firmware, Vedge-100, Vedge-1000 and 5 more | 2024-11-21 | 7.8 High |
A vulnerability in the CLI of Cisco SD-WAN Solution could allow an authenticated, local attacker to elevate lower-level privileges to the root user on an affected device. The vulnerability is due to insufficient authorization enforcement. An attacker could exploit this vulnerability by authenticating to the targeted device and executing commands that could lead to elevated privileges. A successful exploit could allow the attacker to make configuration changes to the system as the root user. | ||||
CVE-2019-1621 | 1 Cisco | 1 Data Center Network Manager | 2024-11-21 | 7.5 High |
A vulnerability in the web-based management interface of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to gain access to sensitive files on an affected device. The vulnerability is due to incorrect permissions settings on affected DCNM software. An attacker could exploit this vulnerability by connecting to the web-based management interface of an affected device and requesting specific URLs. A successful exploit could allow the attacker to download arbitrary files from the underlying filesystem of the affected device. | ||||
CVE-2019-1620 | 1 Cisco | 1 Data Center Network Manager | 2024-11-21 | 9.8 Critical |
A vulnerability in the web-based management interface of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to upload arbitrary files on an affected device. The vulnerability is due to incorrect permission settings in affected DCNM software. An attacker could exploit this vulnerability by uploading specially crafted data to the affected device. A successful exploit could allow the attacker to write arbitrary files on the filesystem and execute code with root privileges on the affected device. | ||||
CVE-2019-1602 | 1 Cisco | 6 Nexus 3000, Nexus 3500, Nexus 3600 and 3 more | 2024-11-21 | 7.8 High |
A vulnerability in the filesystem permissions of Cisco NX-OS Software could allow an authenticated, local attacker to access sensitive data that could be used to elevate their privileges to administrator. The vulnerability is due to improper implementation of filesystem permissions. An attacker could exploit this vulnerability by logging in to the CLI of an affected device, accessing a specific file, and leveraging this information to authenticate to the NX-API server. A successful exploit could allow an attacker to make configuration changes as administrator. Note: NX-API is disabled by default. Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5). | ||||
CVE-2019-1600 | 1 Cisco | 16 Firepower 4100, Firepower 9300, Firepower Extensible Operating System and 13 more | 2024-11-21 | 4.4 Medium |
A vulnerability in the file system permissions of Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to access sensitive information that is stored in the file system of an affected system. The vulnerability is due to improper implementation of file system permissions. An attacker could exploit this vulnerability by accessing and modifying restricted files. A successful exploit could allow the attacker to access sensitive and critical files. Firepower 4100 Series Next-Generation Firewalls are affected in versions prior to 2.2.2.91 and 2.3.1.110. Firepower 9300 Series Next-Generation Firewalls are affected in versions prior to 2.2.2.91 and 2.3.1.110. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(25), 8.1(1b), and 8.3(1). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(10) and 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.1(5)N1(1b) and 7.3(3)N1(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5). | ||||
CVE-2019-1596 | 1 Cisco | 6 Nexus 3000, Nexus 3500, Nexus 3600 and 3 more | 2024-11-21 | 7.8 High |
A vulnerability in the Bash shell implementation for Cisco NX-OS Software could allow an authenticated, local attacker to escalate their privilege level to root. The attacker must authenticate with valid user credentials. The vulnerability is due to incorrect permissions of a system executable. An attacker could exploit this vulnerability by authenticating to the device and entering a crafted command at the Bash prompt. A successful exploit could allow the attacker to escalate their privilege level to root. Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5). | ||||
CVE-2019-1593 | 1 Cisco | 9 Nexus 3000, Nexus 3500, Nexus 3600 and 6 more | 2024-11-21 | 7.8 High |
A vulnerability in the Bash shell implementation for Cisco NX-OS Software could allow an authenticated, local attacker to escalate their privilege level by executing commands authorized to other user roles. The attacker must authenticate with valid user credentials. The vulnerability is due to the incorrect implementation of a Bash shell command that allows role-based access control (RBAC) to be bypassed. An attacker could exploit this vulnerability by authenticating to the device and entering a crafted command at the Bash prompt. A successful exploit could allow the attacker to escalate their privilege level by executing commands that should be restricted to other roles. For example, a dev-ops user could escalate their privilege level to admin with a successful exploit of this vulnerability. | ||||
CVE-2019-1592 | 1 Cisco | 28 Nexus 9000, Nexus 92160yc-x, Nexus 92300yc and 25 more | 2024-11-21 | 7.8 High |
A vulnerability in the background operations functionality of Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an authenticated, local attacker to gain elevated privileges as root on an affected device. The vulnerability is due to insufficient validation of user-supplied files on an affected device. An attacker could exploit this vulnerability by logging in to the CLI of the affected device and creating a crafted file in a specific directory on the filesystem. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device. | ||||
CVE-2019-1591 | 1 Cisco | 2 Nexus 9000, Nx-os | 2024-11-21 | 7.8 High |
A vulnerability in a specific CLI command implementation of Cisco Nexus 9000 Series ACI Mode Switch Software could allow an authenticated, local attacker to escape a restricted shell on an affected device. The vulnerability is due to insufficient sanitization of user-supplied input when issuing a specific CLI command with parameters on an affected device. An attacker could exploit this vulnerability by authenticating to the device CLI and issuing certain commands. A successful exploit could allow the attacker to escape the restricted shell and execute arbitrary commands with root-level privileges on the affected device. This vulnerability only affects Cisco Nexus 9000 Series ACI Mode Switches that are running a release prior to 14.0(3d). | ||||
CVE-2019-19107 | 2 Abb, Busch-jaeger | 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more | 2024-11-21 | 6.2 Medium |
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed). |