| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| MKCMS V6.2 has SQL injection via the /ucenter/active.php verify parameter. |
| MKCMS V6.2 has SQL injection via /ucenter/reg.php name parameter. |
|
An Out-of-bounds Write vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS), or Remote Code Execution (RCE) and obtain root privileges on the device.
This issue is caused by use of an insecure function allowing an attacker to overwrite arbitrary memory.
This issue affects Juniper Networks Junos OS SRX Series and EX Series:
* Junos OS versions earlier than 20.4R3-S9;
* Junos OS 21.2 versions earlier than 21.2R3-S7;
* Junos OS 21.3 versions earlier than 21.3R3-S5;
* Junos OS 21.4 versions earlier than 21.4R3-S5;
* Junos OS 22.1 versions earlier than 22.1R3-S4;
* Junos OS 22.2 versions earlier than 22.2R3-S3;
* Junos OS 22.3 versions earlier than 22.3R3-S2;
* Junos OS 22.4 versions earlier than 22.4R2-S2, 22.4R3.
|
| Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device. |
|
Heap based buffer overflow in HTTP Server functionality in Micrium uC-HTTP 3.01.01 allows remote code execution via HTTP request.
|
| D-Link DIR-823G v1.0.2 was found to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via a crafted packet. |
| Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. |
| Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. |
| Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. |
| Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the list parameter in the formSetQosBand function. |
| Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. |
| CandidATS version 3.0.0 allows an external attacker to perform CRUD operations on the application databases. This is possible because the application does not correctly validate the entriesPerPage parameter against SQLi attacks. |
| In the Linux kernel, the following vulnerability has been resolved:
clk: bcm: dvp: Assign ->num before accessing ->hws
Commit f316cdff8d67 ("clk: Annotate struct clk_hw_onecell_data with
__counted_by") annotated the hws member of 'struct clk_hw_onecell_data'
with __counted_by, which informs the bounds sanitizer about the number
of elements in hws, so that it can warn when hws is accessed out of
bounds. As noted in that change, the __counted_by member must be
initialized with the number of elements before the first array access
happens, otherwise there will be a warning from each access prior to the
initialization because the number of elements is zero. This occurs in
clk_dvp_probe() due to ->num being assigned after ->hws has been
accessed:
UBSAN: array-index-out-of-bounds in drivers/clk/bcm/clk-bcm2711-dvp.c:59:2
index 0 is out of range for type 'struct clk_hw *[] __counted_by(num)' (aka 'struct clk_hw *[]')
Move the ->num initialization to before the first access of ->hws, which
clears up the warning. |
| In the Linux kernel, the following vulnerability has been resolved:
USB: core: Fix access violation during port device removal
Testing with KASAN and syzkaller revealed a bug in port.c:disable_store():
usb_hub_to_struct_hub() can return NULL if the hub that the port belongs to
is concurrently removed, but the function does not check for this
possibility before dereferencing the returned value.
It turns out that the first dereference is unnecessary, since hub->intfdev
is the parent of the port device, so it can be changed easily. Adding a
check for hub == NULL prevents further problems.
The same bug exists in the disable_show() routine, and it can be fixed the
same way. |
| Microsoft Entra Jira Single-Sign-On Plugin Elevation of Privilege Vulnerability |
| Open Management Infrastructure (OMI) Remote Code Execution Vulnerability |
| Microsoft Azure Kubernetes Service Confidential Container Elevation of Privilege Vulnerability |
| Microsoft Azure Kubernetes Service Confidential Container Elevation of Privilege Vulnerability |
| Broken Access Control in User Authentication in Avaya Scopia Pathfinder 10 and 20 PTS version 8.3.7.0.4 allows remote unauthenticated attackers to bypass the login page, access sensitive information, and reset user passwords via URL modification. |
| Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function. |