| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization. |
| CB3 SW Version 3.3 and upwards, e-series SW Version 5.0 and upwards allow authenticated access to the RTDE (Real-Time Data Exchange) interface on port 30004 which allows setting registers, the speed slider fraction as well as digital and analog Outputs. Additionally unautheticated reading of robot data is also possible |
| An issue was discovered on XIAOMI XIAOAI speaker Pro LX06 1.52.4. Attackers can get root shell by accessing the UART interface and then they can (i) read Wi-Fi SSID or password, (ii) read the dialogue text files between users and XIAOMI XIAOAI speaker Pro LX06, (iii) use Text-To-Speech tools pretend XIAOMI speakers' voice achieve social engineering attacks, (iv) eavesdrop on users and record what XIAOMI XIAOAI speaker Pro LX06 hears, (v) modify system files, (vi) use commands to send any IR code through IR emitter on XIAOMI XIAOAI Speaker Pro LX06, (vii) stop voice assistant service, (viii) enable the XIAOMI XIAOAI Speaker Pro’ SSH or TELNET service as a backdoor, (IX) tamper with the router configuration of the router in the local area networks. |
| GitLab 7.10 through 12.8.1 has Incorrect Access Control. Under certain conditions where users should have been required to configure two-factor authentication, it was not being required. |
| A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device. |
| A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication. |
| In smsSelected of AnswerFragment.java, there is a way to send an SMS from the lock screen due to a permissions bypass. This could lead to local escalation of privilege on the lock screen with no additional execution privileges needed. User interaction is needed for exploitation.Product: AndroidVersions: Android-10Android ID: A-137102479 |
| diag_tool.cgi on DASAN H660RM GPON routers with firmware 1.03-0022 lacks any authorization check, which allows remote attackers to run a ping command via a GET request to enumerate LAN devices or crash the router with a DoS attack. |
| Various Lexmark products have Incorrect Access Control (issue 2 of 2). |
| Various Lexmark products have Incorrect Access Control (issue 1 of 2). |
| The createComment mutation in the WPGraphQL 0.2.3 plugin for WordPress allows unauthenticated users to post comments on any article, even when 'allow comment' is disabled. |
| An issue was discovered in the WPGraphQL 0.2.3 plugin for WordPress. By querying the 'users' RootQuery, it is possible, for an unauthenticated attacker, to retrieve all WordPress users details such as email address, role, and username. |
| The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation. |
| Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission. |
| Unauthenticated password hash disclosure in the User.getUserPWD method in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to retrieve the GUI password hashes of GUI users. This vulnerability can be exploited by unauthenticated attackers with access to the web interface. |
| eQ-3 Homematic CCU2 prior to 2.47.10 and CCU3 prior to 3.47.10 JSON API has Improper Access Control for Interface.***Metadata related operations, resulting in the ability to read, set and deletion of Metadata. |
| The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default. This could allow an unauthenticated, local attacker connected to the device to access the portal and to make any change to the device. |
| The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote attackers to obtain access via an HTTP session on port 10000, as demonstrated by reading the modem password (which is 1234), or reconfiguring "party mode" or "vacation mode." |
| Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories. |
| An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header. |