| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerChart.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadREGbyID. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegf. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code. |
| The Weintek cMT product line is vulnerable to various improper access controls, which may allow an unauthenticated attacker to remotely access and download sensitive information and perform administrative actions on behalf of a legitimate administrator. |
| eProsima Fast DDS (formerly Fast RTPS) is a C++ implementation of the Data Distribution Service standard of the Object Management Group. Prior to versions 2.13.0, 2.12.2, 2.11.3, 2.10.3, and 2.6.7, an invalid DATA_FRAG Submessage causes a bad-free error, and the Fast-DDS process can be remotely terminated. If an invalid Data_Frag packet is sent, the `Inline_qos, SerializedPayload` member of object `ch` will attempt to release memory without initialization, resulting in a 'bad-free' error. Versions 2.13.0, 2.12.2, 2.11.3, 2.10.2, and 2.6.7 fix this issue. |
| The Weintek cMT product line is vulnerable to code injection, which may allow an unauthenticated remote attacker to execute commands with root privileges on the operation system. |
| The affected On-Premise cnMaestro allows an unauthenticated attacker to access the cnMaestro server and execute arbitrary code in the privileges of the web server. This lack of validation could allow an attacker to append arbitrary data to the logger command. |
| A malicious attacker could exploit the interface of the Fieldcomm Group HART-IP (release 1.0.0.0) by constructing messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device. |
| The affected ThroughTek P2P products (SDKs using versions before 3.1.5, any versions with nossl tag, device firmware not using AuthKey for IOTC conneciton, firmware using AVAPI module without enabling DTLS mechanism, and firmware using P2PTunnel or RDT module) do not sufficiently protect data transferred between the local device and ThroughTek servers. This can allow an attacker to access sensitive information, such as camera feeds. |
| Annke N48PBB (Network Video Recorder) products of version 3.4.106 build 200422 and prior are vulnerable to a stack-based buffer overflow, which allows an unauthorized remote attacker to execute arbitrary code with the same privileges as the server user (root). |