| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality. |
| Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server |
| Modbus Tools Modbus Slave (versions 7.4.2 and prior) is vulnerable to a stack-based buffer overflow in the registration field. This may cause the program to crash when a long character string is used. |
| An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition. |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active. |
| The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. |
| All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization. |
| After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly. |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange. |
| Softing OPC UA C++ SDK (Software Development Kit) versions from 5.59 to 5.64 exported library functions don't properly validate received extension objects, which may allow an attacker to crash the software by sending a variety of specially crafted packets to access several unexpected memory locations. |
| An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other. |
| Navigating to a specific URL with a patient ID number will result in the server generating a PDF of a lab report without authentication and rate limiting. |
| The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure. |
| The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information. |
| A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to exit. |
| A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands. |
| A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges. |
| Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration. |
| A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. |
| A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges. |