| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerECC.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in DIAE_tagHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerPageP_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetDemandAnalysisData. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetCalcTagList. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| A getfile function in MDT AutoSave versions prior to v6.02.06 enables a user to supply an optional parameter, resulting in the processing of a request in a special manner. This can result in the execution of an unzip command and place a malicious .exe file in one of the locations the function looks for and get execution capabilities. |
| An attacker could utilize SQL commands to create a new user MDT AutoSave versions prior to v6.02.06 and update the user’s permissions, granting the attacker the ability to login. |
| An attacker could leverage an API to pass along a malicious file that could then manipulate the process creation command line in MDT AutoSave versions prior to v6.02.06 and run a command line argument. This could then be leveraged to run a malicious process. |
| An attacker can gain knowledge of a session temporary working folder where the getfile and putfile commands are used in MDT AutoSave versions prior to v6.02.06. An attacker can leverage this knowledge to provide a malicious command to the working directory where the read and write activity can be initiated. |
| A function in MDT AutoSave versions prior to v6.02.06 is used to retrieve system information for a specific process, and this information collection executes multiple commands and summarizes the information into an XML. This function and subsequent process gives full path to the executable and is therefore vulnerable to binary hijacking. |
| An attacker could utilize a function in MDT AutoSave versions prior to v6.02.06 that permits changing a designated path to another path and traversing the directory, allowing the replacement of an existing file with a malicious file. |
| An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06. |
| Two buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O Series firmware version 2.2 or earlier may allow a remote attacker to cause a denial-of-service condition. |
| Data can be copied without validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier, which may allow a remote attacker to cause denial-of-service conditions. |
| Improper input validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to execute commands. |
| Five buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to initiate a denial-of-service attack and execute arbitrary code. |
| Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key. |
| Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval. |
| Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. |
| The software does not perform any authentication for critical system functionality. |