Filtered by vendor Codesys
Subscriptions
Filtered by product Control For Iot2000
Subscriptions
Total
12 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2020-12069 | 4 Codesys, Festo, Pilz and 1 more | 114 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 111 more | 2024-10-03 | 7.8 High |
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device. | ||||
CVE-2018-25048 | 1 Codesys | 15 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 12 more | 2024-08-05 | 8.8 High |
The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device. | ||||
CVE-2019-18858 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2024-08-05 | 9.8 Critical |
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. | ||||
CVE-2019-13532 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2024-08-04 | 7.5 High |
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. | ||||
CVE-2019-13548 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2024-08-04 | 9.8 Critical |
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. | ||||
CVE-2019-13542 | 1 Codesys | 10 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 7 more | 2024-08-04 | 6.5 Medium |
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. | ||||
CVE-2019-9009 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2024-08-04 | 7.5 High |
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. | ||||
CVE-2019-9008 | 1 Codesys | 10 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 7 more | 2024-08-04 | 8.8 High |
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. | ||||
CVE-2020-15806 | 1 Codesys | 16 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 13 more | 2024-08-04 | 7.5 High |
CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation. | ||||
CVE-2020-12068 | 1 Codesys | 12 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 9 more | 2024-08-04 | 6.5 Medium |
An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation. | ||||
CVE-2020-10245 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2024-08-04 | 9.8 Critical |
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. | ||||
CVE-2020-7052 | 1 Codesys | 15 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 12 more | 2024-08-04 | 6.5 Medium |
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition. |