Filtered by vendor Juniper
Subscriptions
Filtered by product Ex4100
Subscriptions
Total
5 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-44191 | 2 Juniper, Juniper Networks | 26 Ex2300, Ex2300-c, Ex2300 Multigigabit and 23 more | 2024-09-19 | 7.5 High |
An Allocation of Resources Without Limits or Throttling vulnerability in Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause Denial of Service (DoS). On all Junos OS QFX5000 Series and EX4000 Series platforms, when a high number of VLANs are configured, a specific DHCP packet will cause PFE hogging which will lead to dropping of socket connections. This issue affects: Juniper Networks Junos OS on QFX5000 Series and EX4000 Series * 21.1 versions prior to 21.1R3-S5; * 21.2 versions prior to 21.2R3-S5; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S4; * 22.1 versions prior to 22.1R3-S3; * 22.2 versions prior to 22.2R3-S1; * 22.3 versions prior to 22.3R2-S2, 22.3R3; * 22.4 versions prior to 22.4R2. This issue does not affect Juniper Networks Junos OS versions prior to 21.1R1 | ||||
CVE-2023-44203 | 1 Juniper | 26 Ex2300, Ex2300-24mp, Ex2300-24p and 23 more | 2024-09-17 | 6.5 Medium |
An Improper Check or Handling of Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600 allows a adjacent attacker to send specific traffic, which leads to packet flooding, resulting in a Denial of Service (DoS). When a specific IGMP packet is received in an isolated VLAN, it is duplicated to all other ports under the primary VLAN, which causes a flood. This issue affects QFX5000 series, EX2300, EX3400, EX4100, EX4400 and EX4600 platforms only. This issue affects Juniper Junos OS on on QFX5000 Series, EX2300, EX3400, EX4100, EX4400 and EX4600: * All versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S3; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S2; * 22.1 versions prior to 22.1R3; * 22.2 versions prior to 22.2R3; * 22.3 versions prior to 22.3R2. | ||||
CVE-2024-21595 | 1 Juniper | 16 Ex4100, Ex4400, Ex4600 and 13 more | 2024-09-03 | 7.5 High |
An Improper Validation of Syntactic Correctness of Input vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). If an attacker sends high rate of specific ICMP traffic to a device with VXLAN configured, this causes a deadlock of the PFE and results in the device becoming unresponsive. A manual restart will be required to recover the device. This issue only affects EX4100, EX4400, EX4600, QFX5000 Series devices. This issue affects: Juniper Networks Junos OS * 21.4R3 versions earlier than 21.4R3-S4; * 22.1R3 versions earlier than 22.1R3-S3; * 22.2R2 versions earlier than 22.2R3-S1; * 22.3 versions earlier than 22.3R2-S2, 22.3R3; * 22.4 versions earlier than 22.4R2; * 23.1 versions earlier than 23.1R2. | ||||
CVE-2024-21619 | 1 Juniper | 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more | 2024-08-01 | 5.3 Medium |
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2. | ||||
CVE-2024-21620 | 1 Juniper | 105 Ex2200, Ex2200-c, Ex2200-vc and 102 more | 2024-08-01 | 8.8 High |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an attacker to construct a URL that when visited by another user enables the attacker to execute commands with the target's permissions, including an administrator. A specific invocation of the emit_debug_note method in webauth_operation.php will echo back the data it receives. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S10; * 21.2 versions earlier than 21.2R3-S8; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3-S1; * 23.2 versions earlier than 23.2R2; * 23.4 versions earlier than 23.4R2. |
Page 1 of 1.