CVE-2023-6943 1 Mitsubishielectric 10 Ezsocket, Fr Configurator2, Got1000 and 7 more 2024-11-01 9.8 Critical
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
CVE-2023-6942 1 Mitsubishielectric 10 Ezsocket, Fr Configurator2, Got1000 and 7 more 2024-11-01 7.5 High
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
CVE-2020-14521 1 Mitsubishielectric 60 C Controller Interface Module Utility, C Controller Module Setting And Monitoring Tool, Cc-link Ie Control Network Data Collector and 57 more 2024-09-17 8.3 High
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
CVE-2020-14523 1 Mitsubishielectric 27 Cw Configurator, Fr Configurator2, Gx Works2 and 24 more 2024-09-16 8.3 High
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
CVE-2020-14496 1 Mitsubishielectric 29 Cpu Module Logging Configuration Tool, Cw Configurator, Data Transfer and 26 more 2024-08-04 8.3 High
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
CVE-2020-5603 1 Mitsubishielectric 20 Cpu Module Logging Configuration Tool, Cw Configurator, Em Configurator and 17 more 2024-08-04 7.5 High
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors.
CVE-2020-5602 1 Mitsubishielectric 20 Cpu Module Logging Configuration Tool, Cw Configurator, Em Configurator and 17 more 2024-08-04 7.5 High
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.
CVE-2021-20607 1 Mitsubishielectric 3 Ezsocket, Gx Works2, Melsoft Navigator 2024-08-03 5.5 Medium
Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker.
CVE-2021-20588 1 Mitsubishielectric 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more 2024-08-03 9.8 Critical
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
CVE-2021-20587 1 Mitsubishielectric 41 C Controller Module Setting And Monitoring Tool, Cpu Module Logging Configuration Tool, Cw Configurator and 38 more 2024-08-03 9.8 Critical
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
CVE-2021-20606 1 Mitsubishielectric 3 Ezsocket, Gx Works2, Melsoft Navigator 2024-08-03 5.5 Medium
Out-of-bounds Read vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker.
CVE-2023-5247 1 Mitsubishielectric 4 Gx Works3, Melsoft Iq Appportal, Melsoft Navigator and 1 more 2024-08-02 7.8 High
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.
CVE-2024-26314 3 Iconics, Jungo, Mitsubishielectric 49 Genesis64, Windriver, C Controller Module Setting And Monitoring Tool and 46 more 2024-08-02 7.8 High
Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.