Filtered by vendor Iconics
Subscriptions
Total
29 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-7587 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-11-06 | 7.8 High |
Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for ICONICS GENESIS64 version 10.97.3 and prior, Mitsubishi Electric GENESIS64 version 10.97.3 and prior and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64 or MC Works64. | ||||
CVE-2011-5088 | 1 Iconics | 2 Bizviz, Genesis32 | 2024-09-17 | N/A |
The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a "Workbench32/WebHMI component SetTrustedZone Policy vulnerability." | ||||
CVE-2020-12009 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2024-09-16 | 7.5 High |
A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior. | ||||
CVE-2012-3018 | 1 Iconics | 2 Bizviz, Genesis32 | 2024-09-16 | N/A |
The lockout-recovery feature in the Security Configurator component in ICONICS GENESIS32 9.22 and earlier and BizViz 9.22 and earlier uses an improper encryption algorithm for generation of an authentication code, which allows local users to bypass intended access restrictions and obtain administrative access by predicting a challenge response. | ||||
CVE-2006-6488 | 1 Iconics | 1 Dialog Wrapper Module Activex Control | 2024-08-07 | N/A |
Stack-based buffer overflow in the DoModal function in the Dialog Wrapper Module ActiveX control (DlgWrapper.dll) before 8.4.166.0, as used by ICONICS OPC Enabled Gauge, Switch, and Vessel ActiveX, allows remote attackers to execute arbitrary code via a long (1) FileName or (2) Filter argument. | ||||
CVE-2011-5089 | 1 Iconics | 2 Bizviz, Genesis32 | 2024-08-07 | N/A |
Buffer overflow in the Security Login ActiveX controls in ICONICS GENESIS32 8.05, 9.0, 9.1, and 9.2 and BizViz 8.05, 9.0, 9.1, and 9.2 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a long password. | ||||
CVE-2011-2089 | 1 Iconics | 2 Bizviz, Genesis32 | 2024-08-06 | N/A |
Stack-based buffer overflow in the SetActiveXGUID method in the VersionInfo ActiveX control in GenVersion.dll 8.0.138.0 in the WebHMI subsystem in ICONICS BizViz 9.x before 9.22 and GENESIS32 9.x before 9.22 allows remote attackers to execute arbitrary code via a long string in the argument. NOTE: some of these details are obtained from third party information. | ||||
CVE-2014-0758 | 1 Iconics | 1 Genesis32 | 2024-08-06 | N/A |
An ActiveX control in GenLaunch.htm in ICONICS GENESIS32 8.0, 8.02, 8.04, and 8.05 allows remote attackers to execute arbitrary programs via a crafted HTML document. | ||||
CVE-2016-2289 | 1 Iconics | 1 Webhmi | 2024-08-05 | N/A |
Directory traversal vulnerability in ICONICS WebHMI 9 and earlier allows remote attackers to read configuration files, and consequently discover password hashes, via unspecified vectors. | ||||
CVE-2020-12015 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2024-08-04 | 7.5 High |
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior. | ||||
CVE-2020-12007 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2024-08-04 | 9.8 Critical |
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior. | ||||
CVE-2020-12013 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2024-08-04 | 9.1 Critical |
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior. | ||||
CVE-2020-12011 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2024-08-04 | 9.8 Critical |
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior. | ||||
CVE-2021-27041 | 3 Autodesk, Iconics, Mitsubishielectric | 13 Advance Steel, Autocad, Autocad Architecture and 10 more | 2024-08-03 | 7.8 High |
A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code | ||||
CVE-2021-27040 | 3 Autodesk, Iconics, Mitsubishielectric | 13 Advance Steel, Autocad, Autocad Architecture and 10 more | 2024-08-03 | 3.3 Low |
A maliciously crafted DWG file can be forced to read beyond allocated boundaries when parsing the DWG file. This vulnerability can be exploited to execute arbitrary code. | ||||
CVE-2022-40264 | 1 Iconics | 1 Genesis64 | 2024-08-03 | 6.3 Medium |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user import a project package file crafted by the attacker. | ||||
CVE-2022-33319 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-08-03 | 9.1 Critical |
Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server. | ||||
CVE-2022-33320 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-08-03 | 7.8 High |
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes. | ||||
CVE-2022-33318 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-08-03 | 9.8 Critical |
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server. | ||||
CVE-2022-33317 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2024-08-03 | 7.8 High |
Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. |