Filtered by vendor Siemens
Subscriptions
Filtered by product Scalance Xf-200ba
Subscriptions
Total
8 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-3449 | 13 Checkpoint, Debian, Fedoraproject and 10 more | 172 Multi-domain Management, Multi-domain Management Firmware, Quantum Security Gateway and 169 more | 2024-09-17 | 5.9 Medium |
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). | ||||
CVE-2019-13946 | 1 Siemens | 101 Dk Standard Ethernet Controller, Ek-ertec 200, Ek-ertec 200 Firmware and 98 more | 2024-08-05 | 7.5 High |
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. | ||||
CVE-2019-10927 | 1 Siemens | 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more | 2024-08-04 | 6.5 Medium |
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device. | ||||
CVE-2020-28400 | 1 Siemens | 157 Dk Standard Ethernet Controller Evaluation Kit, Dk Standard Ethernet Controller Evaluation Kit Firmware, Ek-ertec 200 Evaulation Kit and 154 more | 2024-08-04 | 7.5 High |
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. | ||||
CVE-2021-25667 | 1 Siemens | 30 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 27 more | 2024-08-03 | 8.8 High |
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active. | ||||
CVE-2022-36323 | 1 Siemens | 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more | 2024-08-03 | 9.1 Critical |
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. | ||||
CVE-2022-36324 | 1 Siemens | 168 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 165 more | 2024-08-03 | 7.5 High |
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. | ||||
CVE-2022-36325 | 1 Siemens | 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more | 2024-08-03 | 6.8 Medium |
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. |
Page 1 of 1.