Filtered by vendor Controlbyweb Subscriptions
Total 5 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-6333 1 Controlbyweb 6 X-301-24i, X-301-24i Firmware, X-301-i and 3 more 2024-11-21 7.5 High
The affected ControlByWeb Relay products are vulnerable to a stored cross-site scripting vulnerability, which could allow an attacker to inject arbitrary scripts into the endpoint of a web interface that could run malicious javascript code during a user's session.
CVE-2023-23553 1 Controlbyweb 2 X-400, X-400 Firmware 2024-11-21 4.5 Medium
Control By Web X-400 devices are vulnerable to a cross-site scripting attack, which could result in private and session information being transferred to the attacker.
CVE-2023-23551 1 Controlbyweb 2 X-600m, X-600m Firmware 2024-11-21 9.1 Critical
Control By Web X-600M devices run Lua scripts and are vulnerable to code injection, which could allow an attacker to remotely execute arbitrary code.
CVE-2018-18882 1 Controlbyweb 2 X-320m-i, X-320m-i Firmware 2024-11-21 N/A
A stored cross-site scripting (XSS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface.
CVE-2018-18881 1 Controlbyweb 2 X-320m-i, X-320m-i Firmware 2024-11-21 N/A
A Denial of Service (DOS) issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory reset is required to restore the device to an operational state.