Filtered by vendor Gryphonconnect
Subscriptions
Total
10 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-20146 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 9.8 Critical |
An unprotected ssh private key exists on the Gryphon devices which could be used to achieve root access to a server affiliated with Gryphon's development and infrastructure. At the time of discovery, the ssh key could be used to login to the development server hosted in Amazon Web Services. | ||||
CVE-2021-20145 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 7.5 High |
Gryphon Tower routers contain an unprotected openvpn configuration file which can grant attackers access to the Gryphon homebound VPN network which exposes the LAN interfaces of other users' devices connected to the same service. An attacker could leverage this to make configuration changes to, or otherwise attack victims' devices as though they were on an adjacent network. | ||||
CVE-2021-20144 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in the parameters of operation 49 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999. | ||||
CVE-2021-20143 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in the parameters of operation 48 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999. | ||||
CVE-2021-20142 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in the parameters of operation 41 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999. | ||||
CVE-2021-20141 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in the parameters of operation 32 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999. | ||||
CVE-2021-20140 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in the parameters of operation 10 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999. | ||||
CVE-2021-20139 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in the parameters of operation 3 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999. | ||||
CVE-2021-20138 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 8.8 High |
An unauthenticated command injection vulnerability exists in multiple parameters in the Gryphon Tower router’s web interface at /cgi-bin/luci/rc. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the web interface. | ||||
CVE-2021-20137 | 1 Gryphonconnect | 2 Gryphon Tower, Gryphon Tower Firmware | 2024-11-21 | 6.1 Medium |
A reflected cross-site scripting vulnerability exists in the url parameter of the /cgi-bin/luci/site_access/ page on the Gryphon Tower router's web interface. An attacker could exploit this issue by tricking a user into following a specially crafted link, granting the attacker javascript execution in the context of the victim's browser. |
Page 1 of 1.