A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.

Project Subscriptions

Vendors Products
Rockwellautomation Subscribe
1763-l16awa Series A Subscribe
1763-l16awa Series B Subscribe
1763-l16bbb Series A Subscribe
1763-l16bbb Series B Subscribe
1763-l16bwa Series A Subscribe
1763-l16bwa Series B Subscribe
1763-l16dwd Series A Subscribe
1763-l16dwd Series B Subscribe
1766-l32awa Series A Subscribe
1766-l32awa Series B Subscribe
1766-l32awaa Series A Subscribe
1766-l32awaa Series B Subscribe
1766-l32bwa Series A Subscribe
1766-l32bwa Series B Subscribe
1766-l32bwaa Series A Subscribe
1766-l32bwaa Series B Subscribe
1766-l32bxb Series A Subscribe
1766-l32bxb Series B Subscribe
1766-l32bxba Series A Subscribe
1766-l32bxba Series B Subscribe
Ab Micrologix Controller Subscribe
Advisories
Source ID Title
EUVD EUVD EUVD-2017-16872 A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

No history.

Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: icscert

Published:

Updated: 2024-08-05T16:19:29.159Z

Reserved: 2017-04-18T00:00:00

Link: CVE-2017-7901

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Deferred

Published: 2017-06-30T03:29:00.797

Modified: 2025-04-20T01:37:25.860

Link: CVE-2017-7901

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses