A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
Project Subscriptions
| Vendors | Products |
|---|---|
|
Rockwellautomation
Subscribe
|
1763-l16awa Series A
Subscribe
1763-l16awa Series B
Subscribe
1763-l16bbb Series A
Subscribe
1763-l16bbb Series B
Subscribe
1763-l16bwa Series A
Subscribe
1763-l16bwa Series B
Subscribe
1763-l16dwd Series A
Subscribe
1763-l16dwd Series B
Subscribe
1766-l32awa Series A
Subscribe
1766-l32awa Series B
Subscribe
1766-l32awaa Series A
Subscribe
1766-l32awaa Series B
Subscribe
1766-l32bwa Series A
Subscribe
1766-l32bwa Series B
Subscribe
1766-l32bwaa Series A
Subscribe
1766-l32bwaa Series B
Subscribe
1766-l32bxb Series A
Subscribe
1766-l32bxb Series B
Subscribe
1766-l32bxba Series A
Subscribe
1766-l32bxba Series B
Subscribe
Ab Micrologix Controller
Subscribe
|
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2017-16872 | A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device. |
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
No history.
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2024-08-05T16:19:29.159Z
Reserved: 2017-04-18T00:00:00
Link: CVE-2017-7901
No data.
Status : Deferred
Published: 2017-06-30T03:29:00.797
Modified: 2025-04-20T01:37:25.860
Link: CVE-2017-7901
No data.
OpenCVE Enrichment
No data.
EUVD