After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3.

Subscriptions

Vendors Products
Juniper Subscribe

Tracking

Sign in to view the affected projects.

Advisories
Source ID Title
EUVD EUVD EUVD-2018-0850 After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3.
Fixes

Solution

The following software releases have been updated to resolve this specific issue: 15.1R7, 15.1X8.3 and all subsequent releases.


Workaround

There are no known workarounds for this issue. However, once the issue has occurred, it can be restored by performing "commit full" (note: "commit full" is a potentially disruptive command).

History

Mon, 16 Sep 2024 19:15:00 +0000

Type Values Removed Values Added
Title Junos OS: Stateless IP firewall filter rules stop working as expected after reboot or upgrade Junos OS: Stateless IP firewall filter rules stop working as expected after reboot or upgrade

cve-icon MITRE

Status: PUBLISHED

Assigner: juniper

Published:

Updated: 2024-09-16T19:10:58.575Z

Reserved: 2017-11-16T00:00:00.000Z

Link: CVE-2018-0026

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Modified

Published: 2018-07-11T18:29:00.293

Modified: 2024-11-21T03:37:23.333

Link: CVE-2018-0026

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses