A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Project Subscriptions
| Vendors | Products |
|---|---|
|
Siemens
Subscribe
|
6md85
Subscribe
6md86
Subscribe
7ke85
Subscribe
7sa82
Subscribe
7sa86
Subscribe
7sa87
Subscribe
7sd82
Subscribe
7sd86
Subscribe
7sd87
Subscribe
7sj82
Subscribe
7sj85
Subscribe
7sj86
Subscribe
7sk82
Subscribe
7sk85
Subscribe
7sl82
Subscribe
7sl86
Subscribe
7sl87
Subscribe
7ss85
Subscribe
7um85
Subscribe
7ut82
Subscribe
7ut85
Subscribe
7ut86
Subscribe
7ut87
Subscribe
7vk87
Subscribe
Cp100 Firmware
Subscribe
Cp200 Firmware
Subscribe
Cp300 Firmware
Subscribe
Dnp3 Tcp Firmware
Subscribe
En100
Subscribe
Iec104 Firmware
Subscribe
Iec 61850 Firmware
Subscribe
Modbus Tcp Firmware
Subscribe
Profinet Io Firmware
Subscribe
|
Advisories
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2018-3482 | A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
No history.
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: siemens
Published:
Updated: 2024-08-05T08:10:14.145Z
Reserved: 2018-05-25T00:00:00
Link: CVE-2018-11451
No data.
Status : Modified
Published: 2018-07-23T21:29:00.237
Modified: 2024-11-21T03:43:23.707
Link: CVE-2018-11451
No data.
OpenCVE Enrichment
No data.
Weaknesses
EUVD