Description
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Published: 2018-07-23
Score: 7.5 High
EPSS: < 1% Very Low
KEV: No
Impact: n/a
Action: n/a
AI Analysis

No analysis available yet.

Remediation

No remediation available yet.

Tracking

Sign in to view the affected projects.

Advisories
Source ID Title
EUVD EUVD EUVD-2018-3482 A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
History

No history.

Subscriptions

Siemens 6md85 6md86 7ke85 7sa82 7sa86 7sa87 7sd82 7sd86 7sd87 7sj82 7sj85 7sj86 7sk82 7sk85 7sl82 7sl86 7sl87 7ss85 7um85 7ut82 7ut85 7ut86 7ut87 7vk87 Cp100 Firmware Cp200 Firmware Cp300 Firmware Dnp3 Tcp Firmware En100 Iec104 Firmware Iec 61850 Firmware Modbus Tcp Firmware Profinet Io Firmware
cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2024-08-05T08:10:14.145Z

Reserved: 2018-05-25T00:00:00.000Z

Link: CVE-2018-11451

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Modified

Published: 2018-07-23T21:29:00.237

Modified: 2024-11-21T03:43:23.707

Link: CVE-2018-11451

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses