Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "600F0894-2001-4681-8B7C-AE24B3C81EA4", "versionEndExcluding": "1.0.0.58", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCEAE442-EE2A-4F16-90FD-13369A0C972C", "versionEndExcluding": "1.0.1.42", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DEB74216-7276-474B-8339-1A42D4CD17E7", "versionEndExcluding": "1.0.1.28", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "029862D3-6AA0-42E9-955A-2505715BE466", "versionEndExcluding": "1.0.0.130", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3B3F26-401C-4ED0-B871-4B4F8521F369", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9295BC98-9E8D-4812-B2CE-69D848E589DE", "versionEndExcluding": "1.0.3.36", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76", "versionEndExcluding": "1.0.2.52", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39", "versionEndExcluding": "1.0.2.102", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*", "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C", "versionEndExcluding": "1.0.2.104", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*", "matchCriteriaId": "1413C591-D066-4FA2-BEB1-6C60F8645F28", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94398B78-9F11-4AD2-A518-3A81CDD72E88", "versionEndExcluding": "1.0.0.56", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68F195E4-0A6D-400B-8F48-3EA07DC3A3ED", "versionEndExcluding": "1.0.0.56", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56."}, {"lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.58, D7800 versiones anteriores a 1.0.1.42, R6100 versiones anteriores a 1.0.1.28, R7500 versiones anteriores a 1.0.0.130, R7500v2 versiones anteriores a 1.0.3.36, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, WNDR3700v4 versiones anteriores a 1.0.2.102, WNDR4300 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.56 y WNDR4500v3 versiones anteriores a 1.0.0.56."}], "id": "CVE-2018-21113", "lastModified": "2024-11-21T04:02:55.967", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary"}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-04-22T15:15:13.473", "references": [{"source": "cve@mitre.org", "tags": ["Vendor Advisory"], "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://kb.netgear.com/000060438/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Modem-Routers-PSV-2018-0033"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-74"}], "source": "nvd@nist.gov", "type": "Primary"}]}