Show plain JSON{"cisaActionDue": "2022-05-06", "cisaExploitAdd": "2022-04-15", "cisaRequiredAction": "The impacted product is end-of-life and should be disconnected if still in use.", "cisaVulnerabilityName": "Schneider Electric U.motion Builder SQL Injection Vulnerability", "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:u.motion_builder:1.3.4:*:*:*:*:*:*:*", "matchCriteriaId": "D8A4D5E5-EA6D-4E2A-BB01-80EDADB3804E", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered."}, {"lang": "es", "value": "Existe una vulnerabilidad de Inyecci\u00f3n de SQL (CWE-89) en U.motion Builder versi\u00f3n de software 1.3.4, que podr\u00eda generar la ejecuci\u00f3n de c\u00f3digo no deseado cuando un ajuste inapropiado de caracteres es introducido."}], "id": "CVE-2018-7841", "lastModified": "2025-02-07T14:15:45.157", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}, "published": "2019-05-22T20:29:01.480", "references": [{"source": "cybersecurity@se.com", "tags": ["Exploit", "Third Party Advisory", "VDB Entry"], "url": "http://packetstormsecurity.com/files/152862/Schneider-Electric-U.Motion-Builder-1.3.4-Command-Injection.html"}, {"source": "cybersecurity@se.com", "tags": ["Exploit", "Mailing List", "Third Party Advisory"], "url": "http://seclists.org/fulldisclosure/2019/May/26"}, {"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-02"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory", "VDB Entry"], "url": "http://packetstormsecurity.com/files/152862/Schneider-Electric-U.Motion-Builder-1.3.4-Command-Injection.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Mailing List", "Third Party Advisory"], "url": "http://seclists.org/fulldisclosure/2019/May/26"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-02"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-89"}], "source": "nvd@nist.gov", "type": "Primary"}, {"description": [{"lang": "en", "value": "CWE-89"}], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}