A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.

Project Subscriptions

Vendors Products
Siemens Subscribe
Simatic Cp 1626 Subscribe
Simatic Cp 1626 Firmware Subscribe
Simatic Et 200sp Open Controller Cpu 1515sp Pc Subscribe
Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Subscribe
Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware Subscribe
Simatic Et 200sp Open Controller Cpu 1515sp Pc Firmware Subscribe
Simatic Hmi Panel Subscribe
Simatic Hmi Panel Firmware Subscribe
Simatic Net Pc Subscribe
Simatic S7-1200 Cpu 1211c Subscribe
Simatic S7-1200 Cpu 1211c Firmware Subscribe
Simatic S7-1200 Cpu 1212c Subscribe
Simatic S7-1200 Cpu 1212c Firmware Subscribe
Simatic S7-1200 Cpu 1214c Subscribe
Simatic S7-1200 Cpu 1214c Firmware Subscribe
Simatic S7-1200 Cpu 1215c Subscribe
Simatic S7-1200 Cpu 1215c Firmware Subscribe
Simatic S7-1200 Cpu 1217c Subscribe
Simatic S7-1200 Cpu 1217c Firmware Subscribe
Simatic S7-1500 Subscribe
Simatic S7-1500 Cpu 1511c Subscribe
Simatic S7-1500 Cpu 1511c Firmware Subscribe
Simatic S7-1500 Cpu 1512c Subscribe
Simatic S7-1500 Cpu 1512c Firmware Subscribe
Simatic S7-1500 Cpu 1518 Subscribe
Simatic S7-1500 Cpu 1518 Firmware Subscribe
Simatic S7-plcsim Advanced Subscribe
Simatic Step 7 Subscribe
Simatic Tim 1531 Irc Subscribe
Simatic Tim 1531 Irc Firmware Subscribe
Simatic Wincc Subscribe
Simatic Wincc Open Architecture Subscribe
Simatic Wincc Runtime Subscribe
Advisories
Source ID Title
EUVD EUVD EUVD-2019-2643 A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

No history.

Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2024-08-04T22:40:15.230Z

Reserved: 2019-04-08T00:00:00

Link: CVE-2019-10929

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Modified

Published: 2019-08-13T19:15:14.860

Modified: 2024-11-21T04:20:10.487

Link: CVE-2019-10929

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses