{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631", "versionEndExcluding": "1.0.0.75", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*", "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32", "versionEndExcluding": "1.0.0.75", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03798255-94BA-427C-8B2D-0861CD5FF730", "versionEndExcluding": "1.0.0.58", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAE7FDE8-A375-4E10-9A57-F93C35FCF694", "versionEndExcluding": "1.0.3.40", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52E997BC-B5C7-4FBA-9535-6A0BA398F8C3", "versionEndExcluding": "1.0.2.60", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D", "versionEndExcluding": "1.0.4.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1F914AD-70DC-47F5-A2F7-672DBE89C62E", "versionEndExcluding": "1.0.4.12", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "712E83F9-2AC9-45B1-B0D6-E780CB8D9365", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850B682D-1D78-489A-8988-5D588EB975AC", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B0AB512-7926-4D78-87A2-FFBD56F7D2CA", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F58362EC-24C5-4EC3-9475-328469DABFD2", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B49E5051-D9AF-4852-8BDF-6F9C61CB5519", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F1FE395-0B10-4AA8-A178-D87E93CFA5D5", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8517632E-5C50-4A30-A9EE-7205A014619F", "versionEndExcluding": "2.3.0.22", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663F925A-642C-4E4A-9D27-76B6EF6978F6", "versionEndExcluding": "1.0.0.68", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "3DAD97C7-458D-4547-82A4-EC7F4CFB2A90", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB", "versionEndExcluding": "1.0.2.70", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*", "matchCriteriaId": "AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3AC696D-EFAB-4DFF-A908-BCF1D58A4AFD", "versionEndExcluding": "1.0.0.60", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4D8680F5-0C06-4CFC-8BA0-CF85D0438419", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD", "versionEndExcluding": "1.0.0.58", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA", "versionEndExcluding": "1.0.0.58", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*", "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB", "versionEndExcluding": "1.0.0.68", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*", "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D7800 before 1.0.1.44, DM200 before 1.0.0.58, R7500v2 before 1.0.3.40, R7800 before 1.0.2.60, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.22, RBR20 before 2.3.0.22, RBS20 before 2.3.0.22, RBK50 before 2.3.0.22, RBR50 before 2.3.0.22, RBS50 before 2.3.0.22, RBS40 before 2.3.0.22, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.60, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68."}, {"lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D7800 versiones anteriores a 1.0.1.44, DM200 versiones anteriores a 1.0.0.58, R7500v2 versiones anteriores a 1.0.3. 40, R7800 versiones anteriores a 1.0.2.60, R8900 versiones anteriores a 1.0.4.12, R9000 versiones anteriores a 1.0.4.12, RBK20 versiones anteriores a 2.3.0.22, RBR20 versiones anteriores a 2.3.0.22, RBS20 versiones anteriores a 2.3.0. 22, RBK50 versiones anteriores a 2.3.0.22, RBR50 versiones anteriores a 2.3.0.22, RBS50 versiones anteriores a 2.3.0.22, RBS40 versiones anteriores a 2.3.0.22, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1. 0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.60, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68."}], "id": "CVE-2019-20714", "lastModified": "2024-11-21T04:39:09.837", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "LOW", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0"}, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0"}, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary"}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1"}, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-04-16T19:15:24.777", "references": [{"source": "cve@mitre.org", "tags": ["Vendor Advisory"], "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://kb.netgear.com/000061214/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-WiFi-System-PSV-2018-0249"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-79"}], "source": "nvd@nist.gov", "type": "Primary"}]}