The Motorola ACE1000 RTU through 2022-05-02 mishandles firmware integrity. It utilizes either the STS software suite or ACE1000 Easy Configurator for performing firmware updates. In case of the Easy Configurator, firmware updates are performed through access to the Web UI where file system, kernel, package, bundle, or application images can be installed. Firmware updates for the Front End Processor (FEP) module are performed via access to the SSH interface (22/TCP), where a .hex file image is transferred and a bootloader script invoked. File system, kernel, package, and bundle updates are supplied as RPM (RPM Package Manager) files while FEP updates are supplied as S-rec files. In all cases, firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks.
Metrics
Affected Vendors & Products
References
History
No history.
MITRE
Status: PUBLISHED
Assigner: mitre
Published: 2022-07-26T22:10:35
Updated: 2024-08-03T06:48:34.768Z
Reserved: 2022-05-04T00:00:00
Link: CVE-2022-30272
Vulnrichment
No data.
NVD
Status : Analyzed
Published: 2022-07-26T23:15:08.217
Modified: 2024-02-15T03:19:02.693
Link: CVE-2022-30272
Redhat
No data.