thermal/drivers/hisi: Drop second sensor hi3660
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Linux | Linux | unaffected |
|
|||||||||||||||||||||||||||
| Linux | Linux | affected |
|
Configuration 1 [-]
|
No data.
| Vendor | Product | Versions |
|---|---|---|
| Linux | Linux Kernel | — |
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2023-59842 | In the Linux kernel, the following vulnerability has been resolved: thermal/drivers/hisi: Drop second sensor hi3660 The commit 74c8e6bffbe1 ("driver core: Add __alloc_size hint to devm allocators") exposes a panic "BRK handler: Fatal exception" on the hi3660_thermal_probe funciton. This is because the function allocates memory for only one sensors array entry, but tries to fill up a second one. Fix this by removing the unneeded second access. |
No CVSS v4.0
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.164% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
cvssV3_1
|
cvssV3_1
|
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Weaknesses | NVD-CWE-noinfo | |
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* cpe:2.3:o:linux:linux_kernel:4.20:-:*:*:*:*:*:* cpe:2.3:o:linux:linux_kernel:4.20:rc7:*:*:*:*:*:* |
|
| Metrics |
cvssV3_1
|
cvssV3_1
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Linux
Linux linux Kernel |
|
| Vendors & Products |
Linux
Linux linux Kernel |
| Type | Values Removed | Values Added |
|---|---|---|
| References |
| |
| Metrics |
threat_severity
|
cvssV3_1
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: thermal/drivers/hisi: Drop second sensor hi3660 The commit 74c8e6bffbe1 ("driver core: Add __alloc_size hint to devm allocators") exposes a panic "BRK handler: Fatal exception" on the hi3660_thermal_probe funciton. This is because the function allocates memory for only one sensors array entry, but tries to fill up a second one. Fix this by removing the unneeded second access. | |
| Title | thermal/drivers/hisi: Drop second sensor hi3660 | |
| References |
|
|