A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.
History

Tue, 12 Nov 2024 15:15:00 +0000

Type Values Removed Values Added
First Time appeared Seimens
Seimens sinec Ins
Weaknesses CWE-125
CPEs cpe:2.3:a:seimens:sinec_ins:*:*:*:*:*:*:*:*
Vendors & Products Seimens
Seimens sinec Ins
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}


Tue, 12 Nov 2024 13:15:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.
Weaknesses CWE-400
References
Metrics cvssV3_1

{'score': 5.3, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C'}

cvssV4_0

{'score': 6.9, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N'}


cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published: 2024-11-12T12:49:43.155Z

Updated: 2024-11-12T14:25:48.481Z

Reserved: 2024-09-12T11:24:19.243Z

Link: CVE-2024-46891

cve-icon Vulnrichment

Updated: 2024-11-12T14:25:40.779Z

cve-icon NVD

Status : Awaiting Analysis

Published: 2024-11-12T13:15:09.693

Modified: 2024-11-12T15:35:11.240

Link: CVE-2024-46891

cve-icon Redhat

No data.