A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.

Project Subscriptions

Vendors Products
Siemens Subscribe
Intermesh 7177 Hybrid2.0 Subscriber Subscribe
Intermesh 7177 Hybrid 2.0 Subscriber Subscribe
Intermesh 7707 Fire Subscriber Subscribe
Intermesh 7707 Fire Subscriber Firmware Subscribe
Advisories
Source ID Title
EUVD EUVD EUVD-2024-42717 A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.
Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

Wed, 30 Oct 2024 16:15:00 +0000

Type Values Removed Values Added
First Time appeared Siemens intermesh 7177 Hybrid 2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber Firmware
CPEs cpe:2.3:h:siemens:intermesh_7177_hybrid_2.0_subscriber:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:intermesh_7707_fire_subscriber:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:intermesh_7177_hybrid_2.0_subscriber:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:intermesh_7707_fire_subscriber_firmware:*:*:*:*:*:*:*:*
Vendors & Products Siemens intermesh 7177 Hybrid 2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber Firmware

Wed, 23 Oct 2024 19:15:00 +0000

Type Values Removed Values Added
First Time appeared Siemens
Siemens intermesh 7177 Hybrid2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber
CPEs cpe:2.3:a:siemens:intermesh_7177_hybrid2.0_subscriber:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:intermesh_7707_fire_subscriber:*:*:*:*:*:*:*:*
Vendors & Products Siemens
Siemens intermesh 7177 Hybrid2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Wed, 23 Oct 2024 14:30:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.
Weaknesses CWE-306
References
Metrics cvssV3_1

{'score': 7.2, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N'}

cvssV4_0

{'score': 6.9, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N'}


Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2024-10-23T18:16:39.383Z

Reserved: 2024-10-04T16:15:00.392Z

Link: CVE-2024-47902

cve-icon Vulnrichment

Updated: 2024-10-23T18:16:30.484Z

cve-icon NVD

Status : Analyzed

Published: 2024-10-23T15:15:31.163

Modified: 2024-10-30T15:48:39.207

Link: CVE-2024-47902

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses