Impact
Untrusted HL7 data received from external systems is processed by multiple server processes that run with root privileges. The vulnerability allows an attacker able to send crafted HL7 messages from an adjacent network to those processes to execute arbitrary code with system level privileges, as defined by CWE-250.
Affected Systems
CGM CLININET application server is affected. Versions up to 2026.MS3 are confirmed vulnerable; later releases may also be impacted. The product runs on the CGM platform and handles HL7 communication with external medical systems.
Risk and Exploitability
The CVSS score of 9 indicates critical severity. The EPSS score is not available, and the vulnerability is not listed in CISA's KEV catalog, but the nature of the flaw implies it can be actively exploited by an attacker who can reach the HL7 interface. The attack vector is inferred to be over the network where HL7 messages are sent, and the attacker must be able to inject malicious data into those messages.
OpenCVE Enrichment