Description
The CGM CLININET application runs the cgm-updater process listening on an open network port without any authentication.




The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.
Published: 2026-10-23
Score: 6.9 Medium
EPSS: n/a
KEV: No
Impact: Unauthorized network access via unauthenticated cgm-updater process
Action: Apply patch
AI Analysis

Impact

The CGM CLININET application runs the cgm-updater process on an open network port with no authentication, creating a CWE-306 weakness. An attacker on the network can connect to this port without credentials and potentially issue commands, extract sensitive information, or manipulate the device. The lack of authentication directly undermines confidentiality, integrity, and availability of the clinical system.

Affected Systems

CGM CLININET versions up to 2026.MS3, and potentially later releases, are affected. The vulnerability has been confirmed for all releases in that range; the exact scope of newer versions is not yet fully documented.

Risk and Exploitability

The CVSS score of 6.9 indicates moderate severity, and the EPSS score is not available. The vulnerability is not listed in the CISA KEV catalog. The attack vector is network, and the defect requires remote connection to the vulnerable port, which may be exposed in hospital or clinical networks. An attacker with network access can exploit the unauthenticated service to compromise the targeted device.

Generated by OpenCVE AI on October 23, 2026 at 09:21 UTC.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Apply the latest CGM CLININET update or patch released by CGM that secures the cgm-updater service
  • Restrict external network access to the cgm-updater port using firewalls or VPN tunnels
  • Disable the cgm-updater service if it is not required for clinical operations

Generated by OpenCVE AI on October 23, 2026 at 09:21 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Fri, 23 Oct 2026 08:45:00 +0000

Type Values Removed Values Added
Description The CGM CLININET application runs the cgm-updater process listening on an open network port without any authentication. The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.
Title Missing Authentication in CGM CLININET
First Time appeared Cgm
Cgm cgm Clininet
Weaknesses CWE-306
CPEs cpe:2.3:a:cgm:cgm_clininet:*:*:*:*:*:*:*:*
Vendors & Products Cgm
Cgm cgm Clininet
References
Metrics cvssV4_0

{'score': 6.9, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N'}


Subscriptions

Cgm Cgm Clininet
cve-icon MITRE

Status: PUBLISHED

Assigner: CERT-PL

Published:

Updated: 2026-10-23T08:22:59.026Z

Reserved: 2025-03-14T14:55:05.985Z

Link: CVE-2025-30053

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Received

Published: 2026-10-23T09:17:05.170

Modified: 2026-10-23T09:17:05.170

Link: CVE-2025-30053

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-10-23T09:30:11Z

Weaknesses
  • CWE-306

    Missing Authentication for Critical Function