Description
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)
Published: 2025-04-16
Score: 8.7 High
EPSS: < 1% Very Low
KEV: No
Impact: n/a
Action: n/a
AI Analysis

No analysis available yet.

Remediation

No remediation available yet.

Tracking

Sign in to view the affected projects.

Advisories
Source ID Title
EUVD EUVD EUVD-2025-11391 A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)
History

Tue, 19 Aug 2025 15:00:00 +0000

Type Values Removed Values Added
CPEs cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*

Wed, 16 Apr 2025 17:45:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)
Weaknesses CWE-89
References
Metrics cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H'}

cvssV4_0

{'score': 8.7, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}


Subscriptions

Siemens Telecontrol Server Basic
cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2025-04-16T18:00:39.407Z

Reserved: 2025-03-28T07:31:27.306Z

Link: CVE-2025-31349

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Analyzed

Published: 2025-04-16T18:16:06.157

Modified: 2025-08-19T14:53:14.027

Link: CVE-2025-31349

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2025-07-12T15:26:03Z

Weaknesses