In NetX Duo before 6.4.4, the networking support module for Eclipse Foundation ThreadX, there was a potential out of bound read issue in _nx_ip_packet_receive() function when received an Ethernet with type set as IP but no IP data.
Advisories

No advisories yet.

Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

Thu, 16 Oct 2025 14:15:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'poc', 'Technical Impact': 'partial'}, 'version': '2.0.3'}


Thu, 16 Oct 2025 08:15:00 +0000

Type Values Removed Values Added
Description In NetX Duo before 6.4.4, the networking support module for Eclipse Foundation ThreadX, there was a potential out of bound read issue in _nx_ip_packet_receive() function when received an Ethernet with type set as IP but no IP data.
Title Potential out of bound read in _nx_ip_packet_receive()
Weaknesses CWE-125
CWE-126
References
Metrics cvssV4_0

{'score': 6.9, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N'}