CVE-2026-112200

Resource exhaustion from unreleased AR and RPC session on RPC requests with incorrect endianness

Published Oct 29, 2026 CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Description
P-Net before 1.0.3 does not release the Application Relationship (AR) and the RPC session when an RPC request is rejected because its data representation has incorrect endianness. The session and its AR remain allocated, so repeated requests exhaust the available sessions. Once they are exhausted the device no longer answers new RPC requests, including Connect, until it is restarted. A remote unauthenticated attacker can use this to cause a denial of service.

Analysis

AI-generated

Technical impact

The defect in P-Net before version 1.0.3 causes Application Relationship objects and RPC sessions to remain allocated when an RPC request is rejected due to incorrect endianness. This resource exhaustion can cause the device to stop honoring any further RPC calls, including Connect, until a restart occurs, resulting in a denial of service that can be triggered remotely without authentication.

Affected Systems

RT‑Labs P-Net devices running any version before 1.0.3 are vulnerable; this includes all firmware releases that have not applied the 1.0.3 update or later.

Risk and Exploitability

The vulnerability carries a CVSS score of 8.7 and lacks an EPSS score but is not listed in the CISA KEV catalog. The attack vector is remote, authenticated device is not required, and the exploitation requires only the ability to send RPC requests with malformed endianness; repeated abuse can exhaust all RPC sessions, leading to a persistent denial of service until the device restarts.

Remediation

Vendor Solution

Upgrade to P-Net 1.0.3 or later.


OpenCVE Recommended Actions

  • Upgrade to P-Net version 1.0.3 or later
  • Restart the device after applying the update to clear any lingering sessions
  • Monitor RPC service availability and restart logs for signs of resource exhaustion

Generated by OpenCVE AI on October 29, 2026 at 16:31 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Rt-labs
Rt-labs p-net
Vendors & Products Rt-labs
Rt-labs p-net
Type Values Removed Values Added
Description P-Net before 1.0.3 does not release the Application Relationship (AR) and the RPC session when an RPC request is rejected because its data representation has incorrect endianness. The session and its AR remain allocated, so repeated requests exhaust the available sessions. Once they are exhausted the device no longer answers new RPC requests, including Connect, until it is restarted. A remote unauthenticated attacker can use this to cause a denial of service.
Title Resource exhaustion from unreleased AR and RPC session on RPC requests with incorrect endianness
Weaknesses CWE-772
References
Metrics cvssV4_0

{'score': 8.7, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N'}

Weaknesses
  • CWE-772

    Missing Release of Resource after Effective Lifetime

Sources

Status
PUBLISHED
Assigner
rt-labs
Published
Updated
Nov 5, 2026, 9:26 PM
Reserved
Oct 19, 2026, 9:58 AM
Status
Deferred
Published
Oct 29, 2026, 4:17 PM
Modified
Nov 5, 2026, 10:17 PM