Technical impact
FreeSWITCH, a software‑defined telecom stack, suffered a pre‑authentication heap out‑of‑bounds write vulnerability in the mod_xml_rpc WebSocket endpoint. The ws_read_frame() routine incorrectly processes a 64‑bit extended payload length, converting the low 32 bits into a signed number and then narrowing the result. If the signed value becomes negative, the size check is bypassed and the low word is reinterpreted as a large unsigned count, causing the client data to overwrite memory beyond the 64 KiB receive buffer. The overrun can corrupt heap objects such as connection pointers, leading to a crash that terminates all concurrent sessions. Remote code execution has not been demonstrated but the memory corruption could be leveraged to modify program state.
Affected Systems
All FreeSWITCH releases prior to 1.11.2 are affected. The mod_xml_rpc module and the /socket WebSocket endpoint are disabled by default, but can be enabled by site administrators. Any installation with the module loaded and the endpoint exposed to the network is vulnerable.
Risk and Exploitability
The CVSS score of 9.1 indicates critical severity. The EPSS score of 1% suggests a relatively low probability of exploitation at present, but the vulnerability can be triggered by any unauthenticated client that can access the /socket WebSocket upgrade before HTTP authentication, which is a likely attack vector. Based on the description, it is inferred that constructing a malicious Frame with an extended payload length that results in a negative signed value is straightforward for an attacker with network access. The exploit does not require specific privileges and can be performed over the open ports used by FreeSWITCH. The flaw is not yet listed in the CISA KEV catalog, indicating no known public exploits as of now.