CVE-2022-30318 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2024-11-21 9.8 Critical
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
CVE-2022-30316 1 Honeywell 2 Safety Manager, Safety Manager Firmware 2024-11-21 6.8 Medium
Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability.
CVE-2022-30315 1 Honeywell 2 Safety Manager, Safety Manager Firmware 2024-11-21 9.8 Critical
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
CVE-2022-30305 1 Fortinet 2 Fortideceptor, Fortisandbox 2024-11-21 3.6 Low
An insufficient logging [CWE-778] vulnerability in FortiSandbox versions 4.0.0 to 4.0.2, 3.2.0 to 3.2.3 and 3.1.0 to 3.1.5 and FortiDeceptor versions 4.2.0, 4.1.0 through 4.1.1, 4.0.0 through 4.0.2, 3.3.0 through 3.3.3, 3.2.0 through 3.2.2,3.1.0 through 3.1.1 and 3.0.0 through 3.0.2 may allow a remote attacker to repeatedly enter incorrect credentials without causing a log entry, and with no limit on the number of failed authentication attempts.
CVE-2022-30304 1 Fortinet 1 Fortianalyzer 2024-11-21 4.2 Medium
An improper neutralization of input during web page generation vulnerability [CWE-79] in FortiAnalyzer versions prior to 7.2.1, 7.0.4 and 6.4.8 may allow a remote unauthenticated attacker to perform a stored cross site scripting (XSS) attack via the URL parameter observed in the FortiWeb attack event logview in FortiAnalyzer.
CVE-2022-30302 1 Fortinet 1 Fortideceptor 2024-11-21 6.5 Medium
Multiple relative path traversal vulnerabilities [CWE-23] in FortiDeceptor management interface 1.0.0 through 3.2.x, 3.3.0 through 3.3.2, 4.0.0 through 4.0.1 may allow a remote and authenticated attacker to retrieve and delete arbitrary files from the underlying filesystem via specially crafted web requests.
CVE-2022-30286 1 Pyscript 1 Pyscript 2024-11-21 7.5 High
pyscriptjs (aka PyScript Demonstrator) in PyScript through 2022-05-04 allows a remote user to read Python source code.
CVE-2022-30284 1 Python-libnmap Project 1 Python-libnmap 2024-11-21 9 Critical
In the python-libnmap package through 0.7.2 for Python, remote command execution can occur (if used in a client application that does not validate arguments). NOTE: the vendor believes it would be unrealistic for an application to call NmapProcess with arguments taken from input data that arrived over an untrusted network, and thus the CVSS score corresponds to an unrealistic use case. None of the NmapProcess documentation implies that this is an expected use case
CVE-2022-30280 1 Nokia 1 Netact 2024-11-21 8.8 High
/SecurityManagement/html/createuser.jsf in Nokia NetAct 22 allows CSRF. A remote attacker is able to create users with arbitrary privileges, even administrative privileges. The application (even if it implements a CSRF token for the random GET request) does not ever verify a CSRF token. With a little help of social engineering/phishing (such as sending a link via email or chat), an attacker may trick the users of a web application into executing actions of the attacker's choosing. If the victim is a normal user, a successful CSRF attack can force the user to perform state changing requests like transferring funds, changing their email address, and so forth. If the victim is an administrative account, CSRF can compromise the entire web application.
CVE-2022-30278 1 Synopsys 1 Black Duck Hub 2024-11-21 6.1 Medium
A vulnerability in Black Duck Hub’s embedded MadCap Flare documentation files could allow an unauthenticated remote attacker to conduct a cross-site scripting attack. The vulnerability is due to improper validation of user-supplied input to MadCap Flare's framework embedded within Black Duck Hub's Help Documentation to supply content. An attacker could exploit this vulnerability by convincing a user to click a link designed to pass malicious input to the interface. A successful exploit could allow the attacker to conduct cross-site scripting attacks and gain access to sensitive browser-based information.
CVE-2022-30270 1 Motorola 2 Ace1000, Ace1000 Firmware 2024-11-21 9.8 Critical
The Motorola ACE1000 RTU through 2022-05-02 has default credentials. It exposes an SSH interface on port 22/TCP. This interface is used for remote maintenance and for SFTP file-transfer operations that are part of engineering software functionality. Access to this interface is controlled by 5 preconfigured accounts (root, abuilder, acelogin, cappl, ace), all of which come with default credentials. Although the ACE1000 documentation mentions the root, abuilder and acelogin accounts and instructs users to change the default credentials, the cappl and ace accounts remain undocumented and thus are unlikely to have their credentials changed.
CVE-2022-30245 1 Honeywell 1 Alerton Compass 2024-11-21 6.5 Medium
Honeywell Alerton Compass Software 1.6.5 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.
CVE-2022-30244 1 Honeywell 2 Alerton Ascent Control Module, Alerton Ascent Control Module Firmware 2024-11-21 8.0 High
Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated programming writes from remote users. This enables code to be store on the controller and then run without verification. A user with malicious intent can send a crafted packet to change and/or stop the program without the knowledge of other users, altering the controller's function. After the programming change, the program needs to be overwritten in order for the controller to restore its original operational function.
CVE-2022-30243 1 Honeywell 2 Alterton Visual Logic, Alterton Visual Logic Firmware 2024-11-21 8.8 High
Honeywell Alerton Visual Logic through 2022-05-04 allows unauthenticated programming writes from remote users. This enables code to be stored on the controller and then run without verification. A user with malicious intent can send a crafted packet to change and/or stop the program without the knowledge of other users, altering the controller's function. After the programming change, the program needs to be overwritten in order for the controller to restore its original operational function.
CVE-2022-30242 1 Honeywell 2 Alerton Ascent Control Module, Alerton Ascent Control Module Firmware 2024-11-21 6.8 Medium
Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.
CVE-2022-30232 1 Schneider-electric 2 Powerlogic Ion Setup, Powerlogic Ion Setup Firmware 2024-11-21 8 High
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30105 1 Belkin 2 N300, N300 Firmware 2024-11-21 9.8 Critical
In Belkin N300 Firmware 1.00.08, the script located at /setting_hidden.asp, which is accessible before and after configuring the device, exhibits multiple remote command injection vulnerabilities. The following parameters in the [form name] form; [list vulnerable parameters], are not properly sanitized after being submitted to the web interface in a POST request. With specially crafted parameters, it is possible to inject a an OS command which will be executed with root privileges, as the web interface, and all processes on the device, run as root.
CVE-2022-30083 1 Elliegrid 1 Elliegrid 2024-11-21 9.8 Critical
EllieGrid Android Application version 3.4.1 is vulnerable to Code Injection. The application appears to evaluate user input as code (remote).
CVE-2022-30079 1 Netgear 1 R6200 2024-11-21 8.8 High
Command injection vulnerability was discovered in Netgear R6200 v2 firmware through R6200v2-V1.0.3.12 via binary /sbin/acos_service that could allow remote authenticated attackers the ability to modify values in the vulnerable parameter.
CVE-2022-30078 1 Netgear 4 R6200, R6200 Firmware, R6300 and 1 more 2024-11-21 8.8 High
NETGEAR R6200_V2 firmware versions through R6200v2-V1.0.3.12_10.1.11 and R6300_V2 firmware versions through R6300v2-V1.0.4.52_10.0.93 allow remote authenticated attackers to execute arbitrary command via shell metacharacters in the ipv6_fix.cgi ipv6_wan_ipaddr, ipv6_lan_ipaddr, ipv6_wan_length, or ipv6_lan_length parameters.