| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization. |
| A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console. |
| In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication. |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext. |
| In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered. |
| In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries. |
| A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5 |
| Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. An out-of-bounds read overflow can be exploited when a valid user opens a specially crafted, malicious input file due to the lack of validation. |
| Digi International ConnectPort LTS 32 MEI, Firmware Version 1.4.3 (82002228_K 08/09/2018), bios Version 1.2. Successful exploitation of this vulnerability could allow an attacker to upload a malicious file to the application. |
| Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem. |
| Digi International ConnectPort LTS 32 MEI, Firmware Version 1.4.3 (82002228_K 08/09/2018), bios Version 1.2. Multiple cross-site scripting vulnerabilities exist that could allow an attacker to cause a denial-of-service condition. |
| In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser. |
| In Emerson ValveLink v12.0.264 to v13.4.118, a vulnerability in the ValveLink software may allow a local, unprivileged, trusted insider to escalate privileges due to insecure configuration parameters. |
| A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server. |