CVE-2020-27290 1 Hamilton-medical 2 Hamilton-t1, Hamilton-t1 Firmware 2024-11-21 4.3 Medium
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an information disclosure vulnerability in the ventilator allows attackers with physical access to the configuration interface's logs to get valid checksums for tampered configuration files.
CVE-2020-27289 1 Deltaww 1 Cncsoft-b 2024-11-21 7.8 High
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code.
CVE-2020-27288 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
An untrusted pointer dereference has been identified in the way TPEditor(v1.98 and prior) processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution.
CVE-2020-27287 1 Deltaww 1 Cncsoft-b 2024-11-21 7.8 High
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
CVE-2020-27285 1 Redlion 1 Crimson 2024-11-21 9.1 Critical
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.
CVE-2020-27284 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
TPEditor (v1.98 and prior) is vulnerable to two out-of-bounds write instances in the way it processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution.
CVE-2020-27283 1 Redlion 1 Crimson 2024-11-21 5.3 Medium
An attacker could send a specially crafted message to Crimson 3.1 (Build versions prior to 3119.001) that could leak arbitrary memory locations.
CVE-2020-27282 1 Hamilton-medical 2 Hamilton-t1, Hamilton-t1 Firmware 2024-11-21 4.3 Medium
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files.
CVE-2020-27281 1 Deltaww 1 Cncsoft Screeneditor 2024-11-21 7.8 High
A stack-based buffer overflow may exist in Delta Electronics CNCSoft ScreenEditor versions 1.01.26 and prior when processing specially crafted project files, which may allow an attacker to execute arbitrary code.
CVE-2020-27280 1 Deltaww 1 Ispsoft 2024-11-21 7.8 High
A use after free issue has been identified in the way ISPSoft(v3.12 and prior) processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
CVE-2020-27279 1 Redlion 1 Crimson 2024-11-21 7.5 High
A NULL pointer deference vulnerability has been identified in the protocol converter. An attacker could send a specially crafted packet that could reboot the device running Crimson 3.1 (Build versions prior to 3119.001).
CVE-2020-27278 1 Hamilton-medical 2 Hamilton-t1, Hamilton-t1 Firmware 2024-11-21 5.2 Medium
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface.
CVE-2020-27277 1 Deltaww 1 Dopsoft 2024-11-21 7.8 High
Delta Electronics DOPSoft Version 4.0.8.21 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code.
CVE-2020-27276 1 Sooil 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more 2024-11-21 5.7 Medium
SOOIL Developments Co Ltd DiabecareRS,AnyDana-i & AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i & AnyDana-A mobile apps doesn't use adequate measures to authenticate the communicating entities before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the authentication sequence via Bluetooth Low Energy.
CVE-2020-27275 1 Deltaww 1 Dopsoft 2024-11-21 7.8 High
Delta Electronics DOPSoft Version 4.0.8.21 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
CVE-2020-27274 1 Honeywell 1 Opc Ua Tunneller 2024-11-21 7.5 High
Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead to a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233).
CVE-2020-27272 1 Sooil 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more 2024-11-21 5.7 Medium
SOOIL Developments CoLtd DiabecareRS, AnyDana-i, AnyDana-A, The communication protocol of the insulin pump and AnyDana-i,AnyDana-A mobile apps doesn't use adequate measures to authenticate the pump before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the keys and spoof the pump via BLE.
CVE-2020-27270 1 Sooil 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more 2024-11-21 5.7 Medium
SOOIL Developments CoLtd DiabecareRS, AnyDana-i ,AnyDana-A, communication protocol of the insulin pump & AnyDana-i,AnyDana-A mobile apps doesnt use adequate measures to protect encryption keys in transit which allows unauthenticated physically proximate attacker to sniff keys via (BLE).
CVE-2020-27269 1 Sooil 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more 2024-11-21 5.7 Medium
In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i and AnyDana-A mobile applications lacks replay protection measures, which allows unauthenticated, physically proximate attackers to replay communication sequences via Bluetooth Low Energy.
CVE-2020-27268 1 Sooil 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more 2024-11-21 6.5 Medium
In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, a client-side control vulnerability in the insulin pump and its AnyDana-i and AnyDana-A mobile applications allows physically proximate attackers to bypass checks for default PINs via Bluetooth Low Energy.