The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition.
Search vulnerabilities
Cassia Networks Access Controller Path Traversal
An attacker may be able to use minify route with a relative path to view any file on the Cassia Networks Access Controller prior to 2.0.1.
HIWIN Robot System Software version 3.3.21.9869 does not properly address the terminated command source. As a result, an attacker could craft code to disconnect HRSS and the controller and cause a denial-of-service condition.
Fuji Electric D300win Write-what-where condition
Fuji Electric D300win prior to version 3.7.1.17 is vulnerable to a write-what-where condition, which could allow an attacker to overwrite program memory to manipulate the flow of information.
CWE-302 Authentication Bypass by Assumed-Immutable Data in AliveCor Kardia App version 5.17.1-754993421 and prior on Android allows an unauthenticated attacker with physical access to the Android device containing the app to bypass application authentication and alter information in the app.
The physical IoT device of the AliveCor's KardiaMobile, a smartphone-based personal electrocardiogram (EKG) has no encryption for its data-over-sound protocols. Exploiting this vulnerability could allow an attacker to read patient EKG results or create a denial-of-service condition by emitting sounds at similar frequencies as the device, disrupting the smartphone microphone’s ability to accurately read the data. To carry out this attack, the attacker must be close (less than 5 feet) to pick up and emit sound waves.
Advantech R-SeeNet Versions 2.4.19 and prior are vulnerable to path traversal attacks. An unauthorized attacker could remotely exploit vulnerable PHP code to delete .PDF files.
Honeywell Experion PKS and ACE Controllers Relative Path Traversal
Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized files and directories.
Honeywell Experion PKS and ACE Controllers Injection
Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.
Honeywell Experion PKS and ACE Controllers Unrestricted Upload of File with Dangerous Type
Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to unrestricted file uploads, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.
Authentication is currently unsupported in Haas Controller version 100.20.000.1110 when using the “Ethernet Q Commands” service, which allows any user on the same network segment as the controller (even while connected remotely) to access the service and write unauthorized macros to the device.
Haas Controller version 100.20.000.1110 has insufficient granularity of access control when using the "Ethernet Q Commands" service. Any user is able to write macros into registers outside of the authorized accessible range. This could allow a user to access privileged resources or resources out of context.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Red Lion Controls Crimson 3.0 versions 707.000 and prior, Crimson 3.1 versions 3126.001 and prior, and Crimson 3.2 versions 3.2.0044.0 and prior are vulnerable to path traversal. When attempting to open a file using a specific path, the user's password hash is sent to an arbitrary host. This could allow an attacker to obtain user credential hashes.